Installation Parts Provided
1.
Suspension bolts (M10 × 600...4 pcs.)
2.
Nut, washer (M10...16 pcs.)
3.
Spring washer (M10...8 pcs)
4.
Bolt with washer (M8...4 pcs)
5.
Remote control holder fixing screw (M3 × 12...2 pcs.)
6.
Adjusting bolts (...2 pcs.)
7.
Bolt/Nut-Wall Installation (M12 × 25...each 2 pcs.)
8.
Spring washer, washer (M12...each 4 pcs.)
9.
Installation bracket (R, L)
10. Wall mount bracket (R, L)
11. Hook (...2 pcs.)
12. Floor mount bracket
13. Drain hose insulated (Outlet Dia. 20 mm × 1.3 m)
14. Screw -Floor M. Bracket (M4 × 25...2 pcs.)
15. Bolt-wall mount bracket (M10 × 50...4 pcs.)
16. Remote control holder
17. Drain elbow
Applicable piping kit
CZ-4F5, 10AN: C12AT/A12AT, C18AT, A18AT
CZ-52F5, 7, 10AN: C24AT/A24AT
SELECT THE BEST LOCATION
INDOOR UNIT
•
There should not be any heat source or steam near the
unit.
•
There should not be any obstacles blocking the air
circulation.
•
A place where air circulation in the room is good.
•
A place where drainage can be easily done.
•
A
place
where
noise
prevention
is
taken
into
consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
OUTDOOR UNIT
•
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
•
There should not be any animal or plant which could be
affected by hot air discharged.
•
Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
•
Do not place any obstacles which may cause a short
circuit of the discharged air.
•
If piping length is over the common length, additional
refrigerant should be added as shown in the table.
Piping size
Max.
Piping
Length
(m)
Max.
Elevation
(m)
Rated
Model
Gas
Liquid
Length
(m)
Elevation
C12AT/A12AT
1/2”
1/4”
10
5
7.5
5
C18AT/A18AT
1/2”
1/4”
10
8
7.5
5
C24AT/A24AT
5/8”
1/4”
10
8
7.5
5
Installation parts you should purchase*
1.
*Bushing-sleeve
2.
*Sleeve
3.
*Putty (Gum type sealer)
4.
*1/4” copper pipe (Liquid side)
5.
*1/2” or 5/8” copper pipe (Gas side)
6.
*Additional drain hose
7.
*Vinyl tape (Wide)
8.
*Saddle
9.
*Connecting cable
(3-core wire/1.5 mm
2
) - C12AT
(3-core wire/2.5 mm
2
) - C18AT/C24AT
(5-core wire/1.5 mm
2
) - A12AT
(5-core wire/2.5 mm
2
) - A18AT/A24AT
Type designation 245 IEC 57 or heavier cord.
10. *Insulation material (for Gas side piping)
11. *Insulation material (for Liquid side piping)
12. *Vinyl tape (narrow)
13. *Anchor nut
27
CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5
Содержание CS-A12ATP5
Страница 11: ...3 Dimensions 11 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 12: ...12 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 13: ...4 Refrigeration Cycle Diagram 13 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 14: ...5 Block Diagram 14 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 15: ...15 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 16: ...6 Wiring Diagram 16 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 17: ...17 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 39: ...12 Technical Data 39 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 42: ...13 Exploded View 42 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 44: ...15 Exploded View 44 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 54: ...18 1 REMOTE CONTROL 54 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Страница 56: ...56 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 MACC Printed in Malaysia ...