background image

Thank you very much for purchasing Pana-
sonic products. Read this Instruction Manual 
carefully and thoroughly for the correct and 
optimum use of this product. Kindly keep 
this manual in a convenient place for quick 
reference.

CAUTIONS

2

 

 This product has been developed / pro-

duced for industrial use only.

 

 Be sure to use a crimping tool for crimp-

ing work. 

 

 Do not reuse a contact which has been 

crimped once or inserted into the hous-
ing, as its performance cannot be guar-
anteed.

 

 Always connect or disconnect the cable 

attached connector by holding the con-
nector. Never pull the cable, since it may 
cause a cable break.

OUTLINE

1

 

 This is a connector which can connect to 

the 

DPC-100

 series, etc.

Housing: PAP-06V-S

[manufactured by J.S.T. MFG CO., LTD]

Contact: SPHD-001T-P0.5

[manufactured by J.S.T. MFG CO., LTD]

SUITABLE CABLE

3

Note: For the cable length, refer to the Instruction Manual 

of the device to which it is connected.

Conductor cross-
section area

0.12 to 0.32mm

2

 (AWG26 to 22)

Lead wire diameter

ø1.0 to ø1.5mm

Wire material

Soft, twisted copper wire

Lead wire

Lead wire diameter

Conductor cross-section area

1. Use a suitable cable and prepare its end, 

          
below.

*  When processing, make sure that the core 

wires are not scratched or damaged.

ASSEMBLY PROCEDURE

4

In case of cabtyre cable

Lead wire

2.1mm

Lead wire

2.1mm

(20mm)

Sheath

In case of single lead wire

2. Setting the contact in the groove of the 

   
below, insert the lead wire into the contact 
and crimp.

Lead wire

Contact

<Recommended>
Crimping tool: YC-610R (AWG26 to 24)

[manufactured by J.S.T. MFG CO., LTD.]

 YC-611R 

(AWG22)

[manufactured by J.S.T. MFG CO., LTD.]

3. After crimping, make sure to confirm that 

the crimp height is appropriate.

Cable size

S h e a t h   d i -
ameter (mm)

Crimp height (mm)

Core wire

Sheath (Note)

AWG26

1.3

0.6 to 0.7

1.7

AWG24

1.5

0.65 to 0.75

1.8

AWG22

1.4

0.7 to 0.8

1.8

Note: The crimp height of sheath is a reference value.

 

 Also, confirm that crimping is proper, as 

 
In case the crimping is incorrect, cut the 
cable and repeat the procedure from Step 1.

Lead wire

Core wire should be visible

Contact

0.3 to 0.6mm

Crimp height

Good

Not good

Not good

Examples of incorrect crimping

Longer protrusion of core wire

Shorter protrusion of core wire

Incorrect crimping of 
wire sheath

Insulation caught in 
wire barrel

Uncrimped core wire strand

           

contact to the end of the wire inlet of the 
housing.

  
the locking is proper by pulling lightly 
(10N) at the cable.

The pin position differs with the type of 
device connected. Connect correctly after 

device to which it is connected.

Housing

Connector

CN-66A

INSTRUCTION
MANUAL

MJE-CN66A No.0036-06V

http://panasonic.net/id/pidsx/global

 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 
Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.

© Panasonic Industrial Devices SUNX Co., Ltd. 2012

PRINTED IN JAPAN

Отзывы: