Thank you very much for purchasing Pana-
sonic products. Read this Instruction Manual
carefully and thoroughly for the correct and
optimum use of this product. Kindly keep
this manual in a convenient place for quick
reference.
CAUTIONS
2
This product has been developed / pro-
duced for industrial use only.
Be sure to use a crimping tool for crimp-
ing work.
Do not reuse a contact which has been
crimped once or inserted into the hous-
ing, as its performance cannot be guar-
anteed.
Always connect or disconnect the cable
attached connector by holding the con-
nector. Never pull the cable, since it may
cause a cable break.
OUTLINE
1
This is a connector which can connect to
the
DPC-100
series, etc.
Housing: PAP-06V-S
[manufactured by J.S.T. MFG CO., LTD]
Contact: SPHD-001T-P0.5
[manufactured by J.S.T. MFG CO., LTD]
SUITABLE CABLE
3
Note: For the cable length, refer to the Instruction Manual
of the device to which it is connected.
Conductor cross-
section area
0.12 to 0.32mm
2
(AWG26 to 22)
Lead wire diameter
ø1.0 to ø1.5mm
Wire material
Soft, twisted copper wire
Lead wire
Lead wire diameter
Conductor cross-section area
1. Use a suitable cable and prepare its end,
below.
* When processing, make sure that the core
wires are not scratched or damaged.
ASSEMBLY PROCEDURE
4
In case of cabtyre cable
Lead wire
2.1mm
Lead wire
2.1mm
(20mm)
Sheath
In case of single lead wire
2. Setting the contact in the groove of the
below, insert the lead wire into the contact
and crimp.
Lead wire
Contact
<Recommended>
Crimping tool: YC-610R (AWG26 to 24)
[manufactured by J.S.T. MFG CO., LTD.]
YC-611R
(AWG22)
[manufactured by J.S.T. MFG CO., LTD.]
3. After crimping, make sure to confirm that
the crimp height is appropriate.
Cable size
S h e a t h d i -
ameter (mm)
Crimp height (mm)
Core wire
Sheath (Note)
AWG26
1.3
0.6 to 0.7
1.7
AWG24
1.5
0.65 to 0.75
1.8
AWG22
1.4
0.7 to 0.8
1.8
Note: The crimp height of sheath is a reference value.
Also, confirm that crimping is proper, as
In case the crimping is incorrect, cut the
cable and repeat the procedure from Step 1.
Lead wire
Core wire should be visible
Contact
0.3 to 0.6mm
Crimp height
Good
Not good
Not good
Examples of incorrect crimping
Longer protrusion of core wire
Shorter protrusion of core wire
Incorrect crimping of
wire sheath
Insulation caught in
wire barrel
Uncrimped core wire strand
contact to the end of the wire inlet of the
housing.
the locking is proper by pulling lightly
(10N) at the cable.
The pin position differs with the type of
device connected. Connect correctly after
device to which it is connected.
Housing
Connector
CN-66A
INSTRUCTION
MANUAL
MJE-CN66A No.0036-06V
http://panasonic.net/id/pidsx/global
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2012
PRINTED IN JAPAN