---- 15 ----
B420M/MS/MW, B480M/MS/MW,
B570M/MS/MW/D/D-*9, B53D2,
B643M/MS/MW/D/D-*9, B703M/MS/MW,
C603D, C703M/MS/MW/D
Remove lamp cover
Remove screws (3pcs.), and pull the bottom par t of
control plate ass'y.
Tear off the tapes on insulation.
Open the insulation from the front side
Pull the upper portion.)
Remove the damper thermostat from insulation.
Pull the thermo. dial toward you.
.
Then separate the insulation from the control plate.
REFRIGERANT FLOW DIAGRAM
Refrigerant flows in the refrigerating unit as shown in the figure.
Number in the figure of "PIPE LAYOUT" corresponds to number in the refrigerant flow diagram.
To replace damper thermo.
Sealing dial should be put in place.
Seal the gap between the from insulation and the back
insulation by putting tape.
Hook the sensor bulb in place.
DAMPER THERMOSTAT
Screw
Screw
Insulation
Control panel
Thermo. dial
Lamp cover
Control plate
Ass’y
Back insulation
Sealing dial
Sensor tube
Damper
Thermostat
Side Condenser
(Left)
Side Condenser
(Right)
Mullion Dryer
Pipe
Evaporator
Back Condenser
Capillary Tude
Compressor
Dryer
Содержание B480M