- 7 -
Major operating controls and their functions
SDI card
EVF I/F connector [EVF I/F]
The EVF I/F cable
9
from the interface
bracket is connected here.
SDI output 1, 2 connector
[SDI OUT 1, 2]
SDI signals are output from here.
Setting switches
SW NO
OFF
ON
1
EDH
ENABLE DISABLE
SETTING
E350
E860
3 DATA CLIP NORMAL
CLIP
NTSC/PAL
NTSC
PAL
1: EDH <ENABLE/DISABLE>
(Factory setting: ENABLE)
An EDH flag is added to SDI output at
the ENABLE setting.
2: Model selection <E350/E860>
(Factory setting: E350)
When the AW-E350, AW-E650,
AW-E655 or AW-E750 is used, set
this switch at the E350.
When the AW-E860 is used, set this
switch at the E860.
3: DATA CLIP <NORMAL/CLIP>
(Factory setting: NORMAL)
At the NORMAL setting, signal input
is output at the same level at which it
was input.
At the CLIP setting, signal input at
less than 0% is output at 0%, and
signal input at more than 100% is
clipped at 100%.
4: NTSC/PAL switching <NTSC/PAL>
(Factory setting: NTSC)
Leave this switch at the factory setting.