Example of system configuration
$
When the distance between the ROP and the pan/tilt control panel is more than 10 meters
The distance between the ROP and the pan/tilt control panel can be extended up to a maximum of about 1000 meters on the
following condition using the provided cable (refer following specifications) and/or equivalent cables. (Prepare the cables of
required length.)
• Up to 50 meters:
Use the recommended AC adaptor for the power supply of the pan/tilt control panel.
• More than 50 meters: Supply DC 12V to the ROP and the pan/tilt control panel from the recommended AC adaptor.
In this case, it is not necessary to c12V IN.
Specifications for provided cable
Ferrite core
Ferrite core
Use the twist pair cables.
Connector used
Japan Aviation Electronics Industry, Ltd.
Connector: D02-29PF-N-F0
Contact:
D02-22-26P-PKG100
(For AWG 26 to 28)
Case:
DA-C4-J10
Connector used
Japan Aviation Electronics Industry, Ltd.
Connector: D02-29SF-N-F0
Contact:
D02-22-26S-PKG100
(For AWG 26 to 28)
Case:
DA-C4-J10
Shield
Shield