4. Input/output signal settings
4-4. Setting the output signals
4-4-1. Types of output signals
There are five output signal types: PGM, PVW, AUX, MULTI and KEYOUT.
Five lines of output signals can be assigned to OUTPUT1 to 6.
PGM:
This is the main-line output of the switcher; images with wipe, mix, key and other effects added to
them are output.
PVW:
This is the preview output which enables the next operation to be checked in advance.
AUX:
Signals selected by the AUX bus are output.
MULTI:
This is the multi view display output. The multiple input signals and output signals are reduced and
output to one screen.
KEYOUT: This outputs the key signals.
Connector
Signal type
Output (default)
Assignment
PGM1,
SDI
PGM
Cannot be assigned.
OUTPUT1
SDI
MULTI
PGM, PVW, AUX, MULTI,
KEYOut
OUTPUT
SDI
AUX
OUTPUT3 (optional slot 1-1)
ANALOG or DVI
MULTI
OUTPUT4 (optional slot 1-)
ANALOG
AUX
OUTPUT5 (optional slot -1)
ANALOG or DVI
MULTI
OUTPUT6 (optional slot -)
ANALOG
AUX
4-4-2. Assigning the output signals
Assign the output signals to OUTPUT1 to 6.
1
Press the [FUNC] button to light its indicator, and press the [IN/OUT] button to display the IN/OUT menu.
2
Turn [F1] to display the Output sub menu.
3
Turn [F] to select the signal name using the Signal item, and turn [F3] to set the type of output signal using
the Assign item.
<Menu display>
Output Signal Assign
2/11 OUT1 PGM
OUT1~6 PVW
AUX
Multi
KEYOut