background image

Specifications

15

Synchronous terminal

<REF> terminal

In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through)

 

f

If the loop-through output is not used, provide a 75 

Ω

 termination.

In internal sync mode: Black burst output signal 

×

2

 

f

Connector: BNC

 

f

Same field frequencies as those of the system formats supported

 

f

In the 1080/24PsF and 1080/23.98PsF formats, only Genlock mode supported

 

f

In the 1080/23.98PsF format, black burst signals with 10 Field ID (SMPTE318M standard compliant) or Tri-level Sync 

signals supported

<LTC IN> terminal

This is the LTC (linear time code) input terminal

 

f

Connector: BNC

 

f

Impedance: 1 k

Ω

 

f

Level: 1 to 2 V [p-p]

Video delay time

During Standard mode

1 line (H)

When the frame synchronizer is set to [Off], and the up-converter is set to [Off]

1 frame (F)

When the frame synchronizer is set to on, or the up-converter is set to [On]

 

f

When the signals have passed through PinP, DVE, MultiView, down-converter, or DVI-IN, a maximum delay of 1 frame is 

applied in each case.

During 3G mode

2 lines (H)

When the frame synchronizer is set to [Off]

2 frames (F)

When the frame synchronizer is set to [On]

 

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

During 4K mode

1 frame (F)

The frame synchronizer is always on.

 

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

 

f

For details on other added delays, refer to “3G mode/4K mode” in Operating Guide (PDF).

Control terminal

<LAN> terminal

Compatible with 100Base-TX and AUTO-MDIX (For IP control)

 

f

Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable recommended

 

f

Connector: RJ-45

<PANEL> terminal

Compatible with 100Base-TX and AUTO-MDIX (For Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 connection)

 

f

Connection cable (supplied with AV-HS60C1/AV-HS60C2/AV-HS60C4): LAN cable (CAT5E), straight cable, STP 

(Shielded Twisted Pair), 10 m (32.8 ft)

 

f

Connector: RJ-45

<COM1 (M)>/<COM2 (M)>/<COM3 

(M)> terminals

RS-422 control terminal

For master connection for controlling external devices

 

f

Connector: D-sub 9-pin (female) 

×

3, inch screw

<COM4 (M/S)> terminal

RS-422 control terminal

For master/slave connection for controlling external devices

 

f

Connector: D-sub 9-pin (female), inch screw

 

f

Switchable between master connection and slave connection by the menu

<GPI IN> terminal

GPI IN: 18 inputs, general-purpose, photocoupler sensing

ALARM OUT: 1 output, open collector output (negative logic)

 

f

Connector: D-sub 25-pin (female), inch screw

<GPI OUT1>/<GPI OUT2> 

terminals

GPI OUT: 48 outputs, selected from general purpose, tally

Open collector output

 

f

Connector: D-sub 25-pin (female) 

×

2, inch screw

@

@

NOTE

 

t

Use with the same segment is recommended for the devices which are connected to the unit. If the unit is connected to the devices whose segments 
are different, events dependent upon the settings inherent to the network equipment, for instance, may occur. Thoroughly check the connections with 
the devices to which the unit will be connected prior to the start of operation.

Other

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Humidity

10% to 90% (no condensation)

Dimensions (W

×

H

×

D)

482 mm

×

132 mm

×

418 mm (18-31/32 inches

×

5-3/16 inches

×

16-15/32 inches) (excluding protrusions)

3RU

Mass

AV-HS60U1: Approx. 12.6 k

]

 (27.8 lbs.) (excluding accessories)

AV-HS60U2: Approx. 13.5 k

]

 (29.7 lbs.) (excluding accessories)

 

r

For AV-HS60U1E/AV-HS60U2E

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 35 A (Each mains 
input)

Содержание AV-HS60U1P

Страница 1: ...This manual is an excerpted version of the Operating Guide For more information please visit the Panasonic website http pro av panasonic net en manual index html and refer to the Operating Guide PDF...

Страница 2: ...of the power outlet please consult a qualified electrician WARNING To reduce the risk of fire or electric shock do not expose this equipment to rain or moisture To reduce the risk of fire or electric...

Страница 3: ...nt to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generat...

Страница 4: ...has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of...

Страница 5: ...ly be performed by qualified personnel For continued protection against risk of fire replace only with the same type 3 15 AH 250 V fuse for F1 F2 WARNING This equipment is compliant with Class A of CI...

Страница 6: ...se need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse...

Страница 7: ...uency applications as connecting cables When connecting to the DVI signal terminal use a cable with a ferrite core If your apparatus is supplied with ferrite core s they must be attached on cable s fo...

Страница 8: ...ow to read this document r r Abbreviations The following abbreviations are used in this document f f The model numbers of the Main Frames AV HS60U1P AV HS60U2P AV HS60U1E AV HS60U2E are described as A...

Страница 9: ...r and electrical ratings of the unit are indicated on its side panel Installation Refer to the Operating Guide of the AV HS6000 series Accessories f f AC cable AV HS60U1P 1 cable AV HS60U2P 2 cables A...

Страница 10: ...es not have the POWER switch for the power supply 2 f f When turning off the power of the redundant power supply model AV HS60U2 set both POWER switches for the power supply 1 and the power supply 2 t...

Страница 11: ...put ports GPI IN that control the unit externally and an alarm output port ALARM OUT 11 GPI OUT1 GPI OUT2 terminals connector D sub 25 pin female 2 inch screw signal GPI OUT Equipped with 48 output po...

Страница 12: ...4 4 6 4 5 4 7 4 9 4 8 OP STILL1 BUS SHFT 4 SDI IN3 3 SDI IN2 2 SDI IN1 1 Black 12 11 10 SDI IN9 9 SDI IN8 SDI IN11 SDI IN10 8 SDI IN7 7 SDI IN6 6 SDI IN5 5 SDI IN4 Red Red Blue Fig 2 Fig 3 1 Press th...

Страница 13: ...ble is used During 3G mode 16 lines f f Connector BNC 16 only the odd numbered terminals can be used f f The even numbered terminals SDI IN 2 SDI IN 4 SDI IN 32 cannot be used f f SDI IN 25 SDI IN 27...

Страница 14: ...t from the SDI OUT 13 and SDI OUT 15 terminals f f SDI OUT 13 and SDI OUT 15 terminals are equipped with color correctors The same color corrector setting is also applied to SDI OUT 14 and SDI OUT 16...

Страница 15: ...RJ 45 PANEL terminal Compatible with 100Base TX and AUTO MDIX For Control Panel AV HS60C1 AV HS60C2 AV HS60C4 connection f f Connection cable supplied with AV HS60C1 AV HS60C2 AV HS60C4 LAN cable CAT5...

Страница 16: ...them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on...

Отзывы: