25
2. Basic operations
RECALL: This is used to recall the preset memory data and change the panel settings.
Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3)
menu.
Turn [F2], select “RECL” using the MODE item, turn [F3], and set the preset memory number using the NO.
item.
Press the [F4] switch (EXEC) to recall the settings.
Recall settings can be selected for the crosspoint settings.
ENBL
: The data stored in the preset memory is used.
DSBL
: The data stored in the preset memory is not used, and the settings prior to recall are retained.
Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3)
menu.
Turn [F1] to display the PSMEM (2/3) menu.
Turn [F2], and select crosspoint disable (DSBL) or enable (ENBL) using the XPT item.
PSMEM
2/3
XPT
DSBL
ENBL
CLEAR: This is used to clear the preset memory content.
Press the [FUNC] switch to light its indicator, and then press the [MEM] switch to display the PSMEM (1/3)
menu.
Turn [F2], select “CLR” using the MODE item, turn [F3], and set the preset memory number using the NO.
item.
Press the [F4] switch (EXEC) to clear the content.