![Panasonic AN30182A-EVB Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/panasonic/an30182a-evb/an30182a-evb_user-manual_273472011.webp)
11
24
AN30182A-EVB
User’s Guide
for Evaluation Board
Revised
Total Pages
Page
2013-05-15
Automotive & Industrial Systems Company, Panasonic Corporation
Regulations
No.
1824S02E
Figure 10. Register Contents on Operating Window of Serial Controller Software
This section describes register contents on operating window of serial controller software.
For further details, please refer to the register map in section 4.4.
1) every
LDO and DCDC ON/OFF select register
2)
Register for output voltage setup of DCDC1
3)
Register for output voltage setup of DCDC2
4
)
Register for output voltage setup of LDO1
5
)
Register for output voltage setup of LDO2
6
)
Register for output voltage setup of LDO3
7
)
Register for output voltage setup of LDO4
8
)
Register for output voltage setup of LDO5
9
)
Register for output voltage setup of LDO6
10) every
LDO Power save mode select register
11)
LDO1EN Enable
4.3 Register Contents
e.g. LDO1=3.3V:ON (Power save mode)
・1) Write 000H(Address), 04H(Data) : LDO1:ON
・4)
Write 002H(Address), 0FH(Data)
:
LDO1=3.3V
・10)
Write 005H(Address), 01H(Data)
: Power save mode
2)
3)
4)
5)
7)
6)
9)
10)
1)
8)
11)
Note: The parameters above is subject to change for improvement without notice.