KW8M Eco-POWER METER (1A/5ACT input type)
28
6.1.1 Integral Electric Power
・
It displays the integral electric power.
・
Press <SHIFT/
▽
> to shift active power, reactive power, apparent power.
Integral active power
(kWh)
Integral reactive power
(kvarh)
Integral apparent power
(kVAh)
・
Integral electric power is measured and displayed from 0.00 to 9999999.9 (kWh/kvarh/kVAh).
・
The decimal point is changed automatically.
(After reaching the full-scale (9999999.9), the value reverts to 0.00 but continues to measure.)
*Although instantaneous reactive power is “
-
(minus)” value when leading phase and
it shows “
-
(minus)“ in the display, it doesn’t integrate the integral apparent power.
How to reset the integral electric power (active/reactive/apparent)
・
Hold down <SET> and press <MODE> makes integral electric power clear.
(Active power, reactive power and apparent power are reset by each.)
Reset
ON
<SET>
OFF
ON
<MODE>
OFF
0.00 999999.99 1000000.0 9999999.9
[kWh]
Lighting
[kvarh]
Lighting
[kVAh]
Lighting