![Panasonic AKHVF70 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/panasonic/akhvf70/akhvf70_user-manual_3527916012.webp)
12
How to use on-screen menus
(continued)
13
z
z
VIDEO CONFIG menu
_indicates factory default settings.
Item
Set value
Remarks
GAMMA
SELECT
STANDARD
FILM
Selects the gamma curve.
The
FILM
mark appears at the
top left of the screen when FILM is
selected.
STANDARD :
Standard mode
FILM
:
Film mode
FILM GAMMA
VARICAM
OTHER
Selects the type of FILM gamma
mode.
VARICAM :
Shows that FILM_REC
gamma is selected on
the camera
OTHER :
Shows that a mode
other than FILM_REC
gamma is selected on
the camera
Gamma curve (representative)
Input level
Brightness
:
OTHER
:
VARICAM
:
STANDARD
COLOR TEMP.
USER 0
│
63
D93
D65
D56
Selects color temperature.
USER 0 - 63 :
Adjustable settings 0 to 63
(equivalent to a color temperature
range of 3,000 K to 9,300 K)
*
1
D93 :
Equivalent to a color temperature
of 9,300 K
D65 :
Equivalent to a color temperature
of 6,500 K
D56 :
Equivalent to a color temperature
of 5,600 K
SHARPNESS
MODE
HIGH
LOW
Selects the width of edges during
contour correction (during peaking
operation).
HIGH :
Narrow edge
LOW :
Wide edge
SHARPNESS H
0
│
30
Sets the horizontal contour correction
value.
Adds the value to the PEAKING knob
operation.
SHARPNESS V
0
│
30
Sets the vertical contour correction
value.
Adds the value to the PEAKING knob
operation.
MONO
OFF
ON
Switches between color and
monochrome (MONO).
OFF :
Color
ON :
Monochrome
SCAN
NORMAL
UNDER
Sets screen display to underscan or
normal display.
NORMAL :
Normal display
UNDER :
Underscan
*1 Press the SELECT dial and wait until the set value changes to light
blue to change it.
z
z
SYSTEM CONFIG menu
_indicates factory default settings.
Item
Set value
Remarks
UP TALLY
LAMP
HIGH
LOW
OFF
Sets the brightness of the up tally
lamp.
HIGH :
Lights brightly
LOW :
Lights dimly
OFF :
Does not light the up tally
lamp
WFM
OFF
ON
Displays the waveform of the
luminance signal input to the
viewfinder.
OFF :
The waveform is not displayed
ON :
The waveform is displayed
WFM
POSITION
LB
RB
RT
LT
Selects location of WFM waveform
display.
LB :
Left bottom of the screen
RB :
Right bottom of the screen
RT :
Right top of the screen
LT :
Left top of the screen
z
z
HOURS METER menu
_indicates factory default settings.
Item
Set value
Remarks
OPERATION
h
Displays the total number of hours
that the power has been on.
h
*
1
LCD
h
Displays the number of hours that
the backlight has been on.
h
*
1
*1 “
p
h” indicates the time in hours up to 262,800 hours (about
30 years). Hours exceeding 262,800 hours are indicated as “OVER”.
Содержание AKHVF70
Страница 15: ...15 Memo ...