background image

7

Parts and their functions

1

5600K switch [5600K MODE]

This is used to change the amplification rate of the GBR
signals by an electrical circuit to achieve a white balance
that corresponds to the color temperature of 5600K.
When it is pressed, the B video signal is attenuated by
approximately -6 dB, the R video signal is boosted by
approximately 3 dB, and the G video signal is not
attenuated.  Select this switch setting for shooting under a
5600K light source or shooting outdoors.
When the lamp of the switch is off, the white balance is
made to correspond to a color temperature of 3200K.

2

Flare OFF switch [FLARE OFF MODE]

This is used to cancel the flare correction function (which
suppresses the rise of the pedestal in proportion to the
light quantity).  Its lamp lights when the function is
canceled.

3

Black gamma ON switch [BL-K GAMMA ON MODE]

This is used to enable the black gamma function (which
changes the video signal amplification rate in parts where
the light quantity is low).  Its lamp lights when the function
is enabled.

4

Gamma OFF switch [GAMMA OFF MODE]

This is used to cancel the gamma correction function
(which provides the signal level of the video signals with
the reverse characteristics matching the TV video signal
input and light-emitting level characteristics).  Its lamp
lights when the function is canceled.

5

This switch is not supported at the present time.

6

Knee OFF switch [KNEE OFF MODE]

This is used to cancel the knee function that attenuates
those parts of the video signals where a particular level
(knee point) has been exceeded so that they will not
become saturated as easily.  Its lamp lights when the
function is canceled.

7

White clip OFF switch [WHITE CLIP OFF MODE]

This is used to cancel the white clip function by which the
video signal output is clipped (saturated).  Its lamp lights
when the function is canceled.

8

Matrix ON switch [MATRIX ON MODE]

This is used to enable the matrix function by which the
chroma saturation is compensated for the G (green), B
(blue), R (red), Ye (yellow), Cy (cyan) and Mg (magenta)
signals and by which the chroma saturation and hue are
compensated for the I (skin tone) signals.  Its lamp lights
when the function is enabled.

9

HDTV detail OFF switch [HD.DTL OFF MODE]

This is used to cancel the detail enhancer function that
enhances (adjusts the relative hardness/softness) of the
picture quality in the detailed parts of the HDTV video
output.  Its lamp lights when the function is canceled.

:

SDTV detail OFF switch [SD.DTL OFF MODE]

This is used to cancel the detail enhancer function that
enhances (adjusts the relative hardness/softness) of the
picture quality in the detailed parts of the SDTV video
output.  Its lamp lights when the function is canceled.

1

Black shading control switch
[BLACK SHADING CONTROL]

This is used to correct the black shading (the coloring of
black images.)  When it is pressed and its lamp is lighted
and when one of the SHADING R, B or B switches is then
pressed and selected, the adjustment items for the black
shading appear on the LCD display.  The black shading
correction can be adjusted using four of the 16 adjustment
rotary encoders.

HSAW: Horizontal sawtooth wave correction

This is used to correct the coloring of black screen images
in the horizontal direction in the range of -100 to 100.
When the numerical setting is incremented, the video level
at the left of the screen is increased.

HPAR: Horizontal parabola correction

This is used to correct the coloring of black screen images
in the horizontal direction in the range of -100 to 100.
When the numerical setting is incremented, the video level
at the left and right of the screen is increased.

VSAW: Vertical sawtooth wave correction

This is used to correct the coloring of black screen images
in the vertical direction in the range of -100 to 100.  When
the numerical setting is incremented, the video level at the
top of the screen is increased.

CLIP

WHITE

MATRIX

HD. DTL SD. DTL

BLACK

WHITE

R

SHADING

G

B

KNEE

GAMMA

BLK

UNDO

PED

FLAME

GAMMA

GAIN

SYSTEM

FUNC

9

8

;

<

=

>

?

@

2

1

3

4

5

6

7

:

Adjustment item up and down shift switches [

3

4

]

These are used to scroll the control item display indicated by
one of the control item selector switches 

?

up or down.

>

?

Control item selector switches

When these switches are selected (when their lamps are
lighted), the corresponding adjustment items and adjustment
values appear on the LCD display.  The adjustment values
can be changed by one of the 16 adjustment rotary
encoders.

CLIP

WHITE

MATRIX

HD. DTL SD. DTL

BLACK

WHITE

R

SHADING

G

B

KNEE

GAMMA

BLK

UNDO

PED

FLAME

GAMMA

GAIN

SYSTEM

FUNC

CONTROL

>

?

@

A

HSAW

HPAR

VSAW

VPAR

–100

–49

0

+7

Содержание AKHRP931 - RMT PANEL - AKHC930

Страница 1: ...AK HRP931P Before attempting to connect operate or adjust this product please read these instructions completely Remote Operation Panel ...

Страница 2: ...eil numérique de la classe A est conforme à la norme NMB 003 du Canada CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE USE ONLY THE RECOMMENDED ACCESSORIES FCC Note This device complies with Part 15 of the FCC Rules To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications This equipment has been tested ...

Страница 3: ... the designated multi cable is used to connect the ROP and CCU the distance between these two components can be extended to a maximum of 50 meters Contents Overview 3 Accessories 3 Operating precautions 4 Parts and their functions 5 ROP operation panel 5 ROP connector panel 16 Connections 16 System component connections 16 Reference files 16 Calling reference files 16 Storing reference files 16 Ex...

Страница 4: ...F or above 104 F may adversely affect the internal parts Turn off the power before connecting or disconnecting the cables Do not use the ROP outdoors Maintenance Disconnect the multi cable and wipe the panels with a dry cloth To remove stubborn dirt soak a cloth in some diluted kitchen detergent and wring it out well and then wipe the panels gently Caution Avoid using benzine paint thinners and ot...

Страница 5: ... s operations are cancelled protected status when this switch is pressed while its lamp is lighted while the CCU s power and the camera s power is ON However even when the ROP ON switch lamp is off the panel s GAIN FLARE and DTL controls can be operated provided that the active indicator is lighted It is also possible to operate the iris close switch irrespective of the ROP ON switch setting provi...

Страница 6: ...ch CHARACTER This is used to set the characters to be displayed on the PM to ON or OFF 9 OPT FAN CABLE ALARM 1 2 3 1Optical transmission alarm indicator OPT ALARM This is the optical transmission warning indicator Lighted The indicator lights when the optical signals received in the transmission between the camera and CCU are too weak or when a CCU optical transmission receiver unit data error has...

Страница 7: ...D DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quality in the detailed parts of the HDTV video output Its lamp lights when the function is canceled SDTV detail OFF switch SD DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quali...

Страница 8: ... select the video signals targeted for black and white shading correction from among the R G and B signals The lamp of the selected switch lights 4Knee control switch KNEE CONTROL This is selected to adjust the knee slope and knee point When it is selected its lamp lights The menu is two tiered the adjustment items for the knee point are displayed on the first tier and the adjustment items for the...

Страница 9: ... where the white balance was attained in the range of 800 to 800 After the white balance is adjusted 0 is set as the adjustment value VDTL Vertical detail level This is used to adjust the amount of vertical detail HDTL Horizontal detail level This is used to adjust the amount of horizontal detail CRSP Crisp This is used to set the maximum amplitude of the very faint noise components which are remo...

Страница 10: ... to set whether or not to apply zebra to the areas where coring is applied as the skin tones to the Y signals in the PM output PHAS Skin tone area phase This is used to move the areas recognized as the skin tones in the range of 153 to 93 along the Q axis on the color vector display WIDTH Skin tone area width This is used to widen the areas recognized as the skin tones in the range of 1 to 20 alon...

Страница 11: ...ed to remove the very faint noise components below the level set from the skin tone detail components Matrix control switch MATRIX CONTROL This is pressed to change the correction amounts for the R G R B G R G B B R and B G chroma saturation R G R B G R G B 1 0 0 1 1 0 B R B G 0 0 M T X 1 2 G A I N P H A S E C y _ B 0 0 MTX 12 GAIN PHASE These are used to select the following 12 axis matrix adjust...

Страница 12: ...e R B or G shading switch has been selected ANLG CCU analog output setting This is used to set the analog output of the CCU to the HD or SD component O_SEL Output select This is used to set the analog output of the CCU to RGB or YPbPr SYNC Sync waveform addition setting This is used to select whether to add the sync waveform to the analog output TYPE Analog sync phase coarse adjustment This is use...

Страница 13: ...ene or the data in the adjustment data that can be transferred to another camera to be saved in or called from eight files that serve as scene files POWER FAN Fan power switch This is used to set the power of the camera head s fan to ON OFF or AUTO SPEED FAN Fan speed This is used to set the speed of the camera head s fan 2D M Component 2 dimensional low pass filter This is used to set whether to ...

Страница 14: ...e waveform monitor WFM and picture monitor The output mode can be changed by selecting the MSEL and MLINK settings on the fourth tier of the SYSTEM screen If MLINK is set to ON when BLACK SHADING and WHITE SHADING are to be adjusted the monitor display is also switched temporarily in linkage with the R G and B shading switches D Monitor selector switch R R R R R HDTV Y G P M SDTV Y G P M G G G G G...

Страница 15: ...d B pedestal adjustments the R G and B pedestal adjustment values remain unchanged even when the master pedestal is changed M Iris active switch IRIS ACTIVE This makes it possible to adjust the iris When its lamp is off the iris cannot be controlled from this panel If the switch is set to ON and the iris priority is returned to this panel the panel can then exercise iris control N Master pedestal ...

Страница 16: ...OP able be certain to set CCU s camera power switch to OFF This function stores data in the files containing the user s basic settings user files and calls the data from them It is also possible to call data from the file in which the initial camera settings were stored at the factory factory file Calling reference files 1Factory file Press scene file switch 4 while holding down CALL The file call...

Страница 17: ...ENS X0 8 PED IRIS EXT CALL SENSE RANGE G B R PED Remote Operation Panel AK HRP930P 17 Specifications External dimension drawings CCU control Control signals camera CCU control Power supply DC 12 V Tally control signals RCP control Control signals fader control Power supply DC 12 V PREVIEW control Control signals Maximum cable extension distance 50 meters Operating temperature range 32 F to 104 F 0...

Страница 18: ...os Angeles CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panas...

Отзывы: