Connectors
1
2
6
7
8
9
4
5
3
1
<CCU (1 to 6)> connectors
This connector is for serial connections to the CCU.
2
<DC IN> connector
This is an input connector for external DC power supply. Connect this to an external DC power
supply. (10 V - 16 V DC)
3
<LAN> connector
Control the unit using IP control from an external device via this LAN connector (RJ45). Use
the following cables for the connection.
When using a PoE+ Ethernet hub:
LAN cable*
1
(category 5e or higher, straight cable, up to 100 m (328.1 ft))
When not using a PoE+ Ethernet hub:
LAN cable*
1
(category 5 or higher, straight cable, up to 100 m (328.1 ft))
4
<HD SDI OUT> connector
This connector outputs HD SDI signals.
5
<HD SDI IN> connector
This connector inputs HD SDI signals.
6
<WFM> connector
This connector is linked to the [MONITOR R, G, B, SEQ, ENC] (monitor switching) buttons and
outputs the corresponding signals. LOW is output to the selected pin.
7
<AUX> connector
This connector is intended for future use.
8
<SYSTEM> connector
This is the interface connector for the VE function. When the external selection signal is input,
the camera selection switch lights and becomes operable.
9
<SIGNAL GND> terminal
Connect this to the system ground.
*1: STP (shielded twisted pair) cable recommended.
About the <DC IN> connector
■ External DC power supplies
Verify that the external DC power supply complies with the unit's rated voltage before connecting it.
Use an external power supply whose output current is sufficiently higher than total current of all the connected devices.
You can calculate the total current of the connected devices using the following formula.
total power consumption ÷ voltage
An inrush current is generated when the unit is turned on. Insufficient power supply capacity when the unit is turned on may result in mal-
functions.
We recommend using an external power supply that can ensure provision of power that is twice the total power consumption of the unit.
In addition, be sure to use a DC power cord that meets the requirements of your DC power supply.
Check the pin arrays of the external DC power supply's DC output connector and the unit's <DC IN> connector, and be sure to con-
nect with the correct polarities.
Accidentally connecting a +12 V power supply to the GND terminal may result in fire or malfunction.
(Hirose Electric: HA16RA-4P (77))
Accepts DC 12 V inputs from an external power supply. The input voltage range is DC 10 V to 16 V.
1
2
3
4
Pin No.
Function
1
GND
2
NC
3
NC
4
+12 V
- 30 -