CCU menu
-
49
-
SETUP
This is the selection screen for the SETUP menu.
___ indicates factory default settings.
Item
Setting value
Setting details
IRIS SCALE
FULL
2STOP
Set the IRIS display range of the status display screen.
CABLE
CONNECTION
HYBRID
FIBER
Sets the cable used to connect the camera.
HYBRID
Select this when connecting the camera using an optical fiber multi cable.
FIBER
Select this when connecting the camera using only optical fiber.
● When [FIBER] is selected, power will not be supplied to the camera. In addition, the "OPEN" and
"SHORT" errors will not be displayed.
USER
BUTTON1
NONE
CHARA
BARS
Sets the function to be assigned to the [USER1] button on the front panel.
NONE
No assignment
CHARA
Character display, operation
BARS
Color bar ON/OFF
USER
BUTTON2
NONE
CHARA
MENU/USER1
LOCK
BARS
Sets the function to be assigned to the [USER2] button on the front panel.
NONE
No assignment
CHARA
Character display, operation
MENU/USER1 LOCK
Invalidate [MENU] button, [USER1] button
(Function is assigned, but nothing happens when button pressed.)
BARS
Color bar ON/OFF
TALLY
MAKE
V
Select the input format for the TALLY signal.
MAKE
When the TALLY IN H terminal and the TALLY IN C terminal are OPEN, then TALLY=OFF. When
they are MAKE, then TALLY=ON.
•
The TALLY IN H terminal is internally pulled up to +5 V with a 2.2 K resistor through a
protective diode. The maximum current is 20 mA or less.
V
When voltage is applied to the TALLY IN H terminal, TALLY is ON, and when voltage is not
applied, TALLY is OFF. Connect TALLY IN C to GND.
•
A resistor of about 12.4 kΩ is inserted between TALLY IN H and TALLY IN C. The maximum
voltage that can be applied is 24 V, and the maximum current is 20 mA.