INF-51
Item Set
value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
P64
Q64
R64
FLT MODE
0
1
OFF
ON
ON/OFF setting for the fault detection function
Fault detection function:
When the adaptive filter or the PLL drops into a divergent state
at the time of mode switching like search etc., and a status is
detected where no normal signal can be detected over a period
of 5 tracks or more, this function pulls the status of the adaptive
filter or the PLL to the initial status.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
Factory use only
P65
Q65
R65
PLL MONI
0
1
OFF
ON
ON/OFF setting for PLL frequency monitor control
Frequency monitor control:
When a status is detected where the playback clock frequency at
the time of mode switching during palyback is outside the
permissible range set by MONI LIM PB1 for the specified time or
longer, this function automatically pulls the frequency back to the
reference frequency corresponding to the relative speed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
Factory use only
P66
Q66
R66
MONI KINDSEL
1
2
3
ENV
EYEE
EYEO
Selection of monitor signal
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
Use for electrical adjustment
P67
Q67
R67
MONI CHSEL
0
1
2
3
4
OFF
PBL
PBR
RPL
RPR
Selection of monitor channel(Head)
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
Use for electrical adjustment
P68
Q68
R68
ECC MODE
0
1
2
ALL ON
OT OFF
AL OFF
Setting of error correction control
0: Error correction for INNER and OUTER.
1: Error correction only for INNER, but not for OUTER.
2: No error correction for INNER and OUTER.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
P69
Q69
R69
CONCEAL MOD 0
1
ON
OFF
Setting of error revision control
0: Error revision is performed.
1: Error revision is not performed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
P70
Q70
R70
ERROR MODE
0
1
FAST
SLOW
Setting of the error sampling time
0: FAST mode
1: SLOW mode
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
P71, Q70
0
1
ATF
CTL
Tracking mode setting
0: ATF tracking
1: CTL tracking
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
R71
P71
Q71
R71
TRACKING
MOD
2
3
AUTO L
AUTO R
Tracking mode setting
2: L Head tracking
3: R Head tracking
Only DV master tape can use for DV Adjustment.
• The setting is held until exit from 50M ADJUST, 25M ADJUST,DV
ADJUST.
No
Use for electrical adjustment
P72
Q72
R72
TRACKING VAL -128
|
0
|
127
-128
|
0
|
127
Offset value setting for CTL tracking
• Effective only at the time of TRACKING MOD = CTL.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
No
P73
Q73
R73
ATF HEAD
0
1
PB
RP
Head selection for ATF tracking
0: PB head
1: RP head
No
Содержание AJSD955B - DVCPRO50 STUDIO DECK
Страница 3: ...3...
Страница 4: ...4 AJ YA931G AJ YA932G AJ YAC930G...
Страница 6: ...6 AJ SD930P AJ SD955AP...
Страница 7: ...7 AJ YA931G AJ YA932G AJ YAC930G...
Страница 8: ...FCD0211NTIK83K84...
Страница 65: ...INF 56 14 ERROR MESSAGES...
Страница 66: ...INF 57...
Страница 67: ...INF 58...
Страница 72: ...INF 63 16 CIRCUIT BOARD LAYOUT DRAWING...
Страница 105: ...MECH 26 Figure 3 32 3 Figure 3 32 4 Adjust within specification Confirm this value...
Страница 109: ...MECH 30 Figure 3 34 3 Figure 3 34 4 Adjust within specification Confirm this value...
Страница 111: ...MECH 32 Figure 3 35 2 Confirm this value...
Страница 115: ...MECH 36 Figure 3 37 2 Confirm this value...
Страница 220: ...SCHEMATIC DIAGRAMS NOTE BE SURE TO MAKE YOUR ORDERS OF REPLACEMENT PARTS ACCORDING TO PARTS LIST SECTION 8...