For Long and Trouble-Free Operation: Error Messages
159
F
o
r Long
an
d T
roub
le
-F
re
e O
per
a
tio
n
Use the
4
/
5
buttons to move the cursor (*) and the item at the cursor appears on the counter display.
◆
NOTE:
• The HOURS METER does not appear on the counter display when an error is indicated.
Error information
Error
Description
Operation
No.
Message
E-30
TURN POWER OFF
Displayed when an error occurs in reading and writing card data.
To continue operation, turn the power off and then back on again.
STOP
E-37
COMM ERROR
Displayed when a system controller command was not complied to.
To continue operation, turn the power off and then back on again.
STOP
E-38
SYSTEM ERROR
Displayed when the fan motor stops.
To continue operation, turn the power off and then back on again.
STOP
E-39
CONFIG ERROR
Appears when an optional AVC-Intra Codec board (AJ-YBX200G) cannot be
initialized. This may be caused by a board malfunction. Consult your supplier.
STOP
E-BA
BATTERY
Appears when the input DC voltage is below the undercut voltage.
STOP
“HOURS METER” information display
No.
Item
Description
Counter display
Ser
********
Displays the deck’s serial number.
H00
OPERATION
Indicates the number of hours that the unit has been on.
0H~99999H
H30
POWER ON
Indicates the number of times the power has been turned on.
0T~99999T