117
BATTERY/TAPE screen
Item
Variable
range
Remarks
BATT NEAR
END ALARM
ON
OFF
VF
display
USER
ENG
For setting the warning
tone heard when the
battery is near the end of
its charge to ON or OFF.
BATT NEAR
END CANCEL
ON
OFF
USER
ENG
For switching the function
which cancels the warning
tone heard when the
battery is near the end of
its charge to ON or OFF
using the MODE switch.
BATT END
ALARM
ON
OFF
USER
ENG
For setting the warning
tone heard when the
battery is at the end of its
charge to ON or OFF.
BATT REMAIN
FULL
100%
70%
USER
ENG
For selecting the battery
capacity at which “FULL”
is to appear on the LCD
display window as the
remaining battery display
(for all 7 segments to be
lighted).
TAPE NEAR
END ALARM
ON
OFF
USER
ENG
For setting the warning
tone heard when the end
of the tape is near to ON
or OFF.
TAPE NEAR
END TIME
3min
2min
USER
ENG
For setting the remaining
tape time for which the
warning tone is to be
heard when the end of the
tape is near.
TAPE END
ALARM
ON
OFF
USER
ENG
For setting the warning
tone heard when the tape
has reached its end to ON
or OFF.
TAPE REMAIN/
$
3min/
$
5min/
$
USER
ENG
For setting the time for
one segment of the
remaining tape display
indicated on the LCD
display window.
3min/
$
:
One segment is
set to 3 minutes.
5min/
$
:
One segment is
set to 5 minutes.
BATTERY/TAPE screen
Select the settings which match the type of battery
used on this screen.
The warning tone which signals the remaining battery
charge and remaining tape and which is heard during
shooting can be switched off if they prove to be
distracting.
Item
Variable
range
Remarks
BATTERY
SELECT
AJ-BP490
AU-BP402
PRO14
TRIM14
TRIM13
DIGITAL14
DIONIC90
DIONIC160
BP-H90
BP-H100
NP-L50
ENDURA50
ENDURA-D
BP-L60/90
VF
display
USER
ENG
For selecting the type of
battery used.
AJ-BP490 :
AJ-BP490
battery
AU-BP402 :
AU-BP402
battery
PRO14
:
Anton/Bauer
PRO14 battery
TRIM14
:
Anton/Bauer
TRIM14 battery
TRIM13
:
Anton/Bauer
TRIM13 battery
DIGITAL14 :
Anton/Bauer
DIGITAL
battery (14V)
DIONIC90 :
Anton/Bauer
DIONIC90
DIGITAL
battery
DIONIC160 :
Anton/Bauer
DIONIC160
DIGITAL
battery
BP-H90
:
IDX BP-H90
battery
BP-H100
:
IDX BP-H100
battery
NP-L50
:
IDX NP-L50
battery
ENDURA50 :
IDX
ENDURA50
battery
ENDURA-D :
When mounting
the V-mount
adapter plate
made by IDX to
use a digital
battery
BP-L60/90 :
Sony BP-
L60/90 battery
EXT DC IN
SELECT
AC-ADPT
AJ-BP490
AU-BP402
PRO14
TRIM14
BP-H90
BP-H100
BP-L60/90
USER
ENG
For selecting the power
source to be connected to
the DC IN socket.
The underlining in the variable range column indicates the setting in
the preset mode.
Setting menu screens
VTR MAIN MENU (continued)
C U F
C U F
C U F
C U F
C U F
C U F
C U F
C U F
C U F
C U F
03. 英(P89-127) MENU 05.5.18 10:44 ページ117