1. Switch mounting

Mount the switch with the recommended 
panel mounting hole dimensions shown 
in the dimensions.
Contact us if you are considering using a 
panel of other than the recommended 
size and shape.

2. Regarding fastening lead wires to 
terminals

1) When connecting the tab terminals, 
use a .250 Quick-connect and insert the 
terminals straight in.
If they are skewed, the terminals will 
require excessive insertion force.
In addition, there is some variation in the 
insertion force required for different 
receptacles from different manufacturers, 
so confirm how much force is needed 

under actual conditions.
Do not solder wires onto tab terminals.
2) With manual soldering: Complete the 
soldering connection work within 3 
seconds with the tip of the soldering iron 
(60W soldering iron) at a temperature of 
420°C or lower, and take care not to 
apply any force to the terminal area.
Avoid touching the switch with soldering 
iron.
3) The terminals should be connected in 
such a way that they are not under 
constant stress from the connecting 
wires.
4) Terminal material is copper alloy which 
may discolor due to finger’s oil or after a 
long time. But that discoloration does not 
effect actual performance.

3. Resistance to chemicals

To clean the switch unit, use a neutral 
detergent diluted with water.
Do not use acidic or alkaline solvents as 
they may damage the switch.
Furthermore, be careful not to get any of 
the detergent solution inside of the switch 
while cleaning it.

4. Environment

Avoid using and storing these switches in 
a location where they will be exposed to 
corrosive gases, silicon, or high dust 
levels, all of which can have an adverse 
effect on the contacts.

5. Take care not to drop the product as 
it may impair perfomance.

1. Outline of UL1054 test

Overload test AJ9: 20A 250V AC
(Power factor 0.75 to 0.8)
50 operation
Endurance test AJ9: 16A 250V AC
(Power factor 0.75 to 0.8)
6

×

10

3

 operation

After testing, temperature rise of 
terminals should be less than 30

°

C and 

no abnormality should be observed in 
characteristics.

2. Outline of EN61058-1 test

After switching 5 

×

 10

3

 times on the 

above load condition at both 85

°

C and 

25

±

10

°

C, temperature rise of terminals 

should be less than 55

°

C and no 

abnormality should be observed in 
characteristics.

+

5

0

24A

50 to 100ms

J9: 16A

AC: 250V
(Power factor 0.6)

2 sec.

4 sec.

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Содержание AJ9 (J9)

Страница 1: ... end of the part number We ask customers who are currently using products with cadmium containing contacts no F at the end of the part number to please make the switch to models with cadmium free contacts When switching operating life may differ depending on the load Please be sure to verify this by conducting an evaluation using actual equipment RoHS Directive compatibility information http www n...

Страница 2: ...k connect terminal 1 pole ON OFF AJ911010 9F ON ON AJ911110 3F 2 pole ON OFF AJ921010 9F ON ON AJ921110 3F PC board terminal 1 pole ON OFF AJ911020 9F ON ON AJ911120 3F 2 pole ON OFF AJ921020 9F ON ON AJ921120 3F Actuator indication 0 No indication 1 indication 2 indication 9 AJ9 switch Poles 1 1 pole 2 2 pole Actuator color Remark 2 W White B Black R Red Z Dark gray H Light gray L Blue G Green Y ...

Страница 3: ... AJ911101 3F AJ911102 3F 2 pole ON OFF AJ921001 3F AJ921002 3F ON ON AJ921101 3F AJ921102 3F Soldering compatible with 250 Quick connect terminal 1 pole ON OFF AJ911011 3F AJ911012 3F ON ON AJ911111 3F AJ911112 3F 2 pole ON OFF AJ921011 3F AJ921012 3F ON ON AJ921111 3F AJ921112 3F PC board terminal 1 pole ON OFF AJ911021 3F AJ911022 3F ON ON AJ911121 3F AJ911122 3F 2 pole ON OFF AJ921021 3F AJ9210...

Страница 4: ...Max 30 C UL1054 from 6 103 ope to 104 Max 55 C EN61058 1 Vibration resistance 10 to 55 Hz at double amplitude of 1 5mm Shock resistance Min 294m s2 30 G Actuator strength 40 N 4 08kgf for 1 minute operating direction Tensile terminal strength 100 N 10 2kgf for 1 minute or more Pull push direction Ambient temperature 25 C to 85 C Not freezing below 0 C Flame retardancy UL94V 0 Tracking resistance M...

Страница 5: ...neral tolerance 0 5 2 Soldering compatible with 250 Quick connect terminal 6 35 R1 5 R0 9 34 11 1 4 4 9 7 Remark Dimensions other than listed above are same as those of 250 Quick connect terminal 3 PC board terminal PC board pattern ON ON 34 11 3 6 3 5 1 2 0 1 1 2 0 1 4 5 0 1 4 5 0 1 7 11 11 11 11 2 pole 1 pole Remark Dimensions other than listed above are same as those of 250 Quick connect termin...

Страница 6: ...lloy which may discolor due to finger s oil or after a long time But that discoloration does not effect actual performance 3 Resistance to chemicals To clean the switch unit use a neutral detergent diluted with water Do not use acidic or alkaline solvents as they may damage the switch Furthermore be careful not to get any of the detergent solution inside of the switch while cleaning it 4 Environme...