Electrical Adjustment Procedures
1. Preparation
1-1. Recommended Measurement Equipment (M.EQ) & Servicing Fixtures
No.
NAME
MODEL NO. (Example)
REMARK
1
HD Camera (-recorder)
AJ-HDC20A
EVF Connector 20pin type
2
Digital Volt Meter (D.V.M)
3
Frequency Counter
4
Oscilloscope
5 Resolution
Chart
Charts specification as follows
*16:9 aspect type
*Circles picture described at each corner
6
EHV (Extra High Voltage)
Prove
Use for “2-6. Focus Adj.”
7
Screwdriver, Hex wrench
Please use Screwdrivers type of made by
plastic.
1-2. Preparation for adjustment
Execute an adjustment under the following condition for precise adjustment.
1. Set Viewfinder horizontally and CRT surface to (A) as follows.
*Part of Northern Hemisphere: A is North direction
*Part of Southern Hemisphere: A is South direction
2. Adjust Angle of Eyepiece to 45 degrees as shown below.
Without specific instruction, set control knobs as follows.
PEAKING knob
: Minimum level
CONTRAST knob : Center
BRIGHT knob
: Center
A
45 deg.