3.2
Wiring the Power Supply
3.2.3 Wiring of Terminal Block
Layout of terminal block for power supply
Pin No. Function
1
+24 V
2
0 V
3
Functional ground
Suitable wires (strand wire)
Size
Nominal cross-
sectional area
Rated temperature
Tightening torque
AWG24 to 16
0.2 to 1.25 mm
2
75
°
C or more
0.5 to 0.55 N
・
m
Wiring method
•
When removing the wire's insulation, be careful not to scratch the core wire.
•
Do not twist the wires to connect them.
•
Do not solder the wires to connect them. The solder may break due to vibration.
•
For tightening the terminal block, use a flat-blade screwdriver with a blade size of 0.5 x 3 mm.
•
After wiring, make sure stress is not applied to the wire.
•
In the terminal block socket construction, if the wire is fastened upon counter-clockwise
rotation of the screw, the connection is faulty. Disconnect the wire, check the terminal hole,
and then re-connect the wire.
1. Remove a portion of the wire's insulation.
2. Insert the wire into the terminal block until it contacts the back side.
3. Tighten the screw clockwise to fix the wire in place.
3-7
Содержание AIG707WCL1G2
Страница 1: ......
Страница 8: ...Before You Start vi ...
Страница 9: ...1 System Configuration ...
Страница 12: ...System Configuration 1 4 ...
Страница 13: ...2 Names and Functions of Parts ...
Страница 16: ...Names and Functions of Parts 2 4 ...
Страница 17: ...3 Installation and Wiring ...
Страница 32: ...Installation and Wiring 3 16 ...
Страница 33: ...4 Troubleshooting ...
Страница 43: ...5 Specifications ...
Страница 48: ...Specifications 5 2 Dimensions 5 2 1 GT707 Main Unit Dimensions Unit mm Panel cutout dimensions Unit mm 5 6 ...
Страница 50: ...Specifications 5 8 ...
Страница 51: ...Record of changes Manual No Date Record of Changes WUME GT707H 01 Aug 2015 1st Edition ...
Страница 52: ......
Страница 53: ......
Страница 54: ......