Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Pressure Sensor/PS-A (ADP5)
Rating
Item
Standard type (with glass base)
Remarks
Type of pressure
Gauge pressure
Pressure medium
Air
✽
1
Rated pressure (kPa)
±100
−100
25
50
100
200
500
1,000
Max. applied pressure
Twice of the rated pressure
1.5 times
the rated
pressure
Ambient temperature
−10 °C to +60 °C
14 °F to +140 °F
(no freezing or condensation)
Storage temperature
−20 °C to +85 °C
−4 °F to +185 °F
(no freezing or condensation)
Drive voltage
5±0.25 V
Temperature compensation range
0 °C to 50 °C
32 °F to 122 °F
Offset voltage
2.5±0.05
0.5±0.05 V
✽
2, 3, 5
Rated output voltage
4.5±0.05
(+when
+100kPa)
4.5±0.05 V
✽
2, 3, 5
Overall accuracy
±1.25 %FS
✽
3, 4, 5
Current consumption
Max. 10 mA
✽
2, 3
Output impedance
15
Ω
(Typical)
✽
2
Source current
Max. 0.2 mA
✽
2, 3
Sink current
Max. 2 mA
✽
2, 3
Item
Economy type (without glass base)
Remarks
Type of pressure
Gauge pressure
Pressure medium
Air
✽
1
Rated pressure (kPa)
40
Max. applied pressure
Twice of the rated pressure
Ambient temperature
−5 °C to +50 °C
23 °F to +122 °F
(no freezing or condensation)
Storage temperature
−20 °C to +70 °C
−4 °F to +158 °F
(no freezing or condensation)
Drive voltage
3±0.15 V
Temperature compensation range
5 °C to 45 °C
41 °F to 113 °F
Offset voltage
0.3±0.09 V
✽
2, 3, 5
Span voltage
2.4±0.03 V
✽
2, 3, 5
Offset voltage temperature
characteristics
±4.0 %FS
✽
3, 4, 5
Sensitivity temperature
characteristics
1.3 %FS
✽
3, 4, 5
Current consumption
Max. 3 mA
✽
2
Output impedance
20
Ω
(Typical)
✽
2, 3
Source current
Max. 0.15 mA
✽
2, 3
Sink current
Max. 1.5 mA
✽
2, 3
Notes :
✽
1 Please consult us for pressure media other than air.
✽
2 Indicates output when temperature is 25 °C
77 °F
.
✽
3 Indicates output when drive voltage is 5 V. Although output fl uctuates due to fl uctuations in the drive voltage, this is not included.
✽
4 Overall accuracy indicates the accuracy of the offset voltage and rated output voltage at a temperature compensation range of 0 to 50 °C
32 to 122 °F
.
✽
5 Accuracy is the value at the time of our shipping. Please set Zero-point calibration function on your products in order to safely use if the offset voltage is shifted.
Notes :
✽
1 Please consult us for pressure media other than air.
✽
2 Indicates output when temperature is 25 °C
77 °F
.
✽
3 Indicates output when drive voltage is 3 V. Although output fl uctuates due to fl uctuations in the drive voltage, this is not included.
✽
4 Indicates from output value at 25 °C
77 °F
and the change of output at 5 and 45 °C
41 to 113 °F
.
✽
5 Accuracy is the value at the time of our shipping. Please set Zero-point calibration function on your products in order to safely use if the offset voltage is shifted.
●
Standard type
●
Economy type
Feb. 2019
01