background image

 
 
 

Panasonic Electric Works Fire & Security Technology Europe AB 

 

Citadellsvägen 23, SE-211 18 Malmö, Sweden 

Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 

[email protected] • www.panasonic-fire-security.com 

 

Fire alarm systems 

Alert annunciation units 

1735 and 1736 

 

Control and indicating unit for alert annunciation 

 

Compact size 

Alert annunciation unit 

When the 

A

lert 

A

nnunciation function shall 

be used in the systems EBL512 & EBL128 
an 

AA

 unit is required to present the 

AA

 

alarms and for the related manoeuvres, i.e. 
to acknowledge / reset the alarms.  For a 
detailed description of the 

AA 

function, see 

Planning and Operating instructions for the 
system respectively.   

 

Point or zone alarm presentation is as in the 
c.i.e. it is connected to.  When there are 
queued alarms in the system, you can scroll 
amongst them.  All or selected alarms will 
be presented in the unit's display (LCD, 
2x40 characters with back-light).  A user 
definable text message will be presented 
together with each alarm, if programmed in 
the c.i.e.  Furthermore, > 617 texts can for 
selected alarms be stored in the unit and will 
in that case be shown, instead of the texts 
sent from the c.i.e. for these alarms.  A built-
in buzzer will sound to indicate a not 
acknowledged 

AA

 alarm.  The unit is power 

supplied via the c.i.e. or ext. power supply. 

LEDs, push buttons etc. 

The unit has the following LEDs: 

 

Fire

 and 

Alarms queued

, indicating fire 

alarm / 

AA

 alarm. 

 

Operation

, indicating that the 

AA

 

function is enabled in the system.  
Normally a time channel is used to 
enable this function. 

 

Fire brigade alerted

, indicating that the 

"Fire brigade tx" output is activated in 
the c.i.e. because: 

-

  the activated alarm is not an 

AA 

alarm 

-

  the 

AA

 function has been ended, e.g. 

the acknowledge or investigation time 
has run out, etc. 

 

Acknowledge

, indicating that the 

AA

 

alarm has been acknowledged. 

The unit has the following push buttons: 

 

Alarms queued

, used to scroll amongst 

the alarms. 

 

Acknowledge

, used to acknowledge an 

AA

 alarm and hereby also silence the 

buzzer. 

 

Reset

, used to reset an 

AA 

alarm. 

1735

 has the designation texts in Swedish. 

1736

 has a neutral front for other languages, 

see the opposite side of this page.  (This 
front also holds one extra LED & two extra 
push buttons.) 

Compact size 

The compact size enclosure is made of grey 
high impact ABS.  Fitted with a supple-
mentary "O" ring gasket, it will comply with 
IP61, in respect of dust and moisture.  The 
unit has no door, i.e. the front is accessed 
directly, when required.  The push buttons 
are disabled until they are supposed to be 
used.  The unit shall be wall mounted.  Two 
compression glands are attached. 

SW mode and address setting 

The display and the push buttons are used to 
set the 

SW mode

 and 

address

.   

The SW modes are described on the 
opposite side of this page. 

Product application 

The units are intended for indoor use and in 
dry premises.  They are intended to be used 
in the systems EBL512 & EBL128.  An 
External FBP / DU interface board 1587 is 
required in the EBL512 c.i.e. and a 4552 
Transceiver component in the EBL128 c.i.e. 

Отзывы: