Chapter 2. Error Codes and Screen Messages
18
DigitalFlow™ GM868 Service Manual
2.2 E0: No Error
Problem:
No error condition currently exists.
Cause:
This message appears briefly to confirm that the response to another error message has corrected the
problem.
Action:
No action is required.
2.3 E1: Low Signal
Problem:
Poor ultrasonic signal strength or the signal exceeds the limits entered via the
User Program.
Cause:
Poor signal strength may be caused by a defective cable, a flowcell problem, a defective transducer or a
problem in the electronics console. A signal that exceeds the programmed limits is probably caused by
the entry of an improper value in the
SETUP SIGNL
submenu of the
User Program.
Action:
Using the procedures in Chapter 3,
Diagnostics, check the components listed above. Also, check the
value programmed into the
SETUP SIGNL
submenu, as described in the
Operator’s Manual.
2.4 E2: Sound Speed Error
Problem:
The sound speed exceeds the limits programmed in the
SETUP SIGNL
submenu of the
User Program.
Cause:
The error may be caused by incorrect programming, poor flow conditions or poor transducer spacing.
Action:
Compare the measured sound speed to tabulated nominal values for the fluid being used and correct
any programming errors. Refer to Chapter 3,
Diagnostics, to correct any flowcell and/or transducer
problems.
2.5 E3: Velocity Range
Problem:
The velocity exceeds the limits programmed in the
SETUP
submenu of the
User Program.
Cause:
This error may be caused by the entry of improper programming data or by poor flow conditions and/or
excessive turbulence.
Action:
Make sure the actual flow rate is within the programmed limits. See the
Programming Manual for details.
Refer to Chapter 3,
Diagnostics, to correct any flowcell and/or transducer problems.
Содержание DigitalFlow GM868
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 9: ...DigitalFlow GM868 Service Manual vii Contents...
Страница 10: ...Contents viii DigitalFlow GM868 Service Manual...
Страница 26: ...Chapter 1 Calibration DigitalFlow GM868 Service Manual 16...
Страница 38: ...Chapter 3 Diagnostics 28 DigitalFlow GM868 Service Manual no content intended for this page...
Страница 48: ...Chapter 4 Parts Replacement 38 DigitalFlow GM868 Service Manual no content intended for this page...
Страница 60: ...Appendix B Optional Enclosures 50 DigitalFlow GM868 Service Manual no content intended for this page...
Страница 66: ...Warranty 56 DigitalFlow GM868 Service Manual...
Страница 70: ...60 DigitalFlow GM868 Service Manual no content intended for this page...
Страница 71: ......