Chapter 2.
20
Model CTF878 Startup Guide
Figure 7: Locating Damping Material with a CFT-PI Clamping Fixture Installed
2.1.9
Applying DMP-3 Damping Material
For some applications, particularly on higher-temperature pipes, DMP-3 compound should be used.
Note:
If the pipe temperature is over 150°F, a PDJ pipe damping jacket with DMP-3 damping material applied is
required (see Installing the PDJ Damping Jacket on page 23).
Preparing the Pipe
To prepare the pipe for DMP-3 application:
1.
Remove any loose paint or rust from the pipe surface with a file or emery cloth. If the finish is mirror-smooth,
roughen the surface.
TOP VIEW
SIDE VIEW
CFT-PI CLAMPING FIXTURE
DAMPING MATERIAL
Содержание CTF878
Страница 1: ...panametrics com Flow 910 254U Rev A AUG 2021 Model CTF878 Clamp On Tag Flowmeter Startup Guide...
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 6: ...Warranty iv Model CTF878 Startup Guide no content intended for this page...
Страница 8: ...Contents vi Model CTF878 Startup Guide...
Страница 76: ...Model CTF878 Startup Guide 68...
Страница 96: ...Appendix A 88 Model CTF878 Startup Guide...
Страница 99: ...Model CTF878 Startup Guide 91 Appendix B 9 21 10 22 11 23 12 24...
Страница 100: ...Appendix B 92 Model CTF878 Startup Guide...
Страница 104: ...Index 96 Doc Tittle Manual Type...
Страница 106: ......
Страница 107: ......