4.8
Transducer Specifications
4.8.1
C-RL Transducer Numbers 301, 302, 307 and 308
Table 2:
Specification
Transducer Number
301
302
307
308
Primary Use
Mid-sized pipes,
high temperature
Small pipes,
high temperature
Mid-size pipes,
very high
temperature
Small pipes,
very high
temperature
Installation Type
Clamp-on
Material of Construction
316 stainless steel and plastic
Pipe Sizes
>2 to 12”
(>50 to 300 mm)
3/4 to 2”
(20 to 50 mm)
>2 to 12”
(>50 to 300 mm)
3/4 to 2”
(20 to 50 mm)
Clamping Fixture
CFG-V4, CFG-V8,
CFG-V12
CFG-V1, CFG-V4
CFG-V4, CFG-V8,
CFG-V12
CFG-V1
Operating Frequency
500 kHz
1.0 MHz
500 kHz
1.0 MHz
Electrical Rating
200 V peak-to-peak, 5 mA
Process Temperature Range
-40 to 176
o
C (-40 to 349
o
F)
-40 to 230
o
C (-40 to 446
o
F)
North American Certification -
Explosion-proof
General Purpose
European Certification -
Flameproof
General Purpose
North American Certification -
Weatherproof
IP66, TYPE 4X
200Vpp, 5mA
European Certification -
Weatherproof
IP 66
Note:
The transducer is protected by a suitable fuse located in the flowmeter electronics. The fuse has a rating
corresponding with the short circuit current of the power supply.