TECHNICAL SPECIFICATIONS

Clamping Level..............................................................................................260V

Capacitance......................................................................................30pf (approx.)

Suppression Modes...........................................................Metallic & Longitudinal

Wires Protected....................................................................2 wire/ 1 pr. (pins 4,5)

F u s e l e s s / A u t o - R e s e t t i n g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y E S

C o n n e c t i o n s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R J - 1 1 / 4 5

Clamping Level................................................................................................27V

Attenuation..............................................................<1 dB from 950MHz - 2.05GHz

<2.4 dB up to 2.2GHz

S h i e l d e d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y E S

Connections......................................................................Gold plated, Female “F”

Clamping Level...............................................................................................0.7V

Attenuation................................................................<1 dB from 50MHz -950MHz

S h i e l d e d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y E S

Connections......................................................................Gold plated, Female “F”

GENERAL

SATELLITE CIRCUIT

Connection......................................................................................1/8" mini-plug

Voltage and Polarity.............................................................12VDC, bi-directional

Current Requirement.....................................................................................30mA

DC TRIGGER

ANT/CATV CIRCUIT

TELEPHONE CIRCUIT

NOISE FILTRATION: 

Filtered Outlet Banks........................................................55 dB (100 KHz - 1 MHz)

High-Current Outlets.......................................................50 dB (100 KHz - 1 MHz)

SURGE PROTECTION: 

UL 1449 Surge Suppression Rating................................................................330V

Protection Modes....................................................................... L - N, L - G, N - G

Initial Clamping Level..........................................................200V Peak, 141V Rms

Response Time...............................................................................................<1ns

Joule Rating........................................................................................1790 Joules

Peak Impulse Current...............................................................................65,000A

Catastrophic Surge Circuit ..............................................................................YES

AC: 

Line Voltage...............................................................................................120VAC

Max Current Rating......................................................................15A (1800 Watts)

Thermal Fuse...................................................................................................YES

Over/Under Voltage Protection.........................................................................YES

O v e r-voltage  shutoff  threshold................................................................132V

Under-voltage shutoff threshold................................................................90V

AC CIRCUIT

Dimensions.......................................................17.25” W x 12” D x 3.5” H
Weight.............................................................................................16 lbs.

CONTACTING PANAMAX

For product and warranty information, dealer information, and other general information contact 
Customer Relations at:

•   Email: 

[email protected]

www.panamax.com

•   Fax 

415-472-5540

800-472-5555

or 

415-499-3900

, 7:30 a.m.- 5 p.m. PST

Design and specifications subject to change without notice due to product improvement.

Содержание MAX 5300

Страница 1: ...MAX 5300 Owner s Manual 150 Mitchell Blvd San Rafael CA 94903 www panamax com...

Страница 2: ...ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power center that meets the power quality needs for each piece of equipment in your entertainm...

Страница 3: ...Telephone Line Protection 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 12 TABLE OF CONTENTS USA Canada 800 472 55...

Страница 4: ...hese components can rapidly draw large amounts of current to replenish their power supply capacitors after thunderous bass notes Line conditioners that utilize coils inductors in series with the AC po...

Страница 5: ...USA Canada 800 472 5555 415 499 3900 Fax 415 472 5540 3 CONNECTION DIAGRAM Multi level noise filter and power controller...

Страница 6: ...On delay for the two High Current Outlets Choose between 0 10 and 30 seconds Outlet Bank 2 Turn Off Switch 3 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 2 Choose betw...

Страница 7: ...unsafe voltage condition Readings above 150VAC will not be accurate due to the meter s damping characteristics Convenience Outlet A single outlet on the front panel of the MAX 5300 provides an easy to...

Страница 8: ...ere is no ground present Line Fault Red LED When this light is ON it is indicating that the wall outlet has a reversed line and neutral wire or there is no ground present This light will remain OFF if...

Страница 9: ...e two examples of components that require a constant supply of power A TiVo video recorder relies on continual power to monitor the cable signal and retain its programmed information A VCR should be c...

Страница 10: ...and receivers have a 12VDC trigger built in and will transmit a constant power signal when turned on and in use This power signal will initiate the startup or shutdown sequence of the MAX 5300 s switc...

Страница 11: ...rcuitry is 700 millivolts 0 7 volts That s less than 1 volt above normal operating levels The circuitry is shielded to prevent interference and has been opti mized to have less than 1dB of signal loss...

Страница 12: ...threshold 90VAC the MAX 5300 will perform the following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blin...

Страница 13: ...t Banks 55 dB 100 KHz 1 MHz High Current Outlets 50 dB 100 KHz 1 MHz SURGE PROTECTION UL 1449 Surge Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Respo...

Страница 14: ...ty documentation for more information What is the difference between a Surge and Spike A spike is a high energy pulse of electricity that lasts for short periods of time a few millisec onds 0 001 seco...

Страница 15: ......

Страница 16: ......

Отзывы: