MAX PRO-SERIES RS-232 COMMAND SPECIFICATIONS

Changes the front panel button status to
ON.  Initiates a power-on sequence if the
previous state is OFF.

Changes the front panel button status to
OFF.  Initiates a power-off sequence if the
previous state is ON.  

(Default)

Initiates a power cycle sequence for the
Switched Outlets only.

Initiates a power cycle sequence for the
High Current Outlets only.

Initiates a power-cycle sequence. Switched
& high-current outlets turn off, followed by
a 10 second delay, followed by a power-on
sequence.

Turns off all outlets.  Forces front panel
button status to OFF.

Disconnects 12V trigger output from 12V
trigger input

12V trigger input passes through to 12V
trigger output   

(Default)

Forces the 12V trigger output to 0V.  Does
not work when trigger is attached to 12V
trigger input.

Forces the 12V trigger output to 12V.  Does
not work when trigger is attached to 12V
trigger input.

Request the status of the 12V trigger input.  PS responds with:

a

12VINHI

if voltage is sensed on the12V input

b

12VINLO

if 0V is sensed on the 12V input

c

BUTTONON

if the ON/OFF button status is ON.

d

BUTTONOFF

if the ON/OFF button status is OFF.

e

12VOUTHI

if the trigger output is ON (+12V)

f

12VOUTLO

if the trigger output is OFF (0V)

Request the status of the outlet banks.  PS responds with:

a

MAINACON

if all outlets (main relay) are ON

b

MAINACOFF

if all outlets are OFF

c

SWITCHEDON

if the switched outlets are ON

d

SWITCHEDOFF

if the switched outlets are OFF

e

HICURRENTON

if the high-current (delayed) outlets are ON

f

HICURRENTOFF

if the high-current outlets are OFF

Request the status of the input voltage

a

NORMAL

if the voltage is within limits

b

OVERVOLTAGE 

if the voltage is greater than 132VAC

c

UNDERVOLTAGE

if the voltage is less than 95VAC

d

RECOVERY 

if recovering from an over/undervoltage state but

has not yet restored power to outlets.

Request that the unit identify itself.  Returns the following:

PANAMAX: MAX 5510-PRO
FW: SFW5510
REV: revision

All commands and queries listed above are transmitted.

2.1 POWERON

2.2

POWEROFF

2.3

CYCLESW

2.4

CYCLEHC

2.5

CYCLE

2.6

ALLOFF

2.7

DETACHTRIG

2.8

ATTACHTRIG

2.9

TRIGOUTLO

2.10

TRIGOUTHI

2.13

?TRIGSTAT

2.14

?OUTLETSTAT

2.15

?PWRSTAT

2.18

?ID

2.19

HELP

1. OVERVIEW

The Panamax Pro-Series product family has a RS232 interface that allows it to communicate with a wide variety of equipment. 

The purpose of this document is to outline the command set used to communicate with the Pro-Series (PS) products. 

Commands and responses are in the form of ASCII character STRINGS TERMINATED 
with ASCII 13, line feed (ASCII 10) or NULL (ASCIØ).

Command String

Description / Response

Command String

Description / Response

2. PORT SETTINGS

Baud Rate: 

9600bps

Data Bits: 

8

Start Bits:

1

Stop Bits:

1

Flow Control:

None

Null modem cable not required.    

DB9 Pinout Diagram

5 4 3 2 1

6 7 8 9

PIN NO.
    1
    2
    3
    4
    5
    6
    7
    8
    9

    SIGNAL
        -
 RECEIVE DATA
TRNSMIT DATA
        -
  GROUND
        -
        -   
        -
        -

3. CONTROLLER COMMANDS

The following are commands made by the controller to Pro-Series products.

Содержание M5510-PRO

Страница 1: ...MAX 5510 PRO ACRegenerator Owner s Manual POWER MAX 5510 PRO ACRegenerator 1690 Corporate Circle Petaluma CA 94954 www panamax com MODEL M5510 PRO...

Страница 2: ...rience were utilized during the development of this model The MAX 5510 Pro has been specifically engineered to enhance the performance and life expectancy of high end Audio Video entertainment gear Th...

Страница 3: ...Plus Protection 9 Automatic Over Under Voltage Protection 9 Technical Specifications 9 RS 232 Command Specification 10 Isolated vs Balanced Power 11 Troubleshooting 12 TABLE OF CONTENTS USA Canada 80...

Страница 4: ...system your combination of components and the quality and routing of interconnected cabling Due to this different results may be observed when comparing picture and sound quality from identical equip...

Страница 5: ...EO R G B H V LAN TELCO CIRCUIT BREAKER Control 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS ISOLATED OUTLETS ALWAYS ON OUTLETS CIRCUIT BREAKER GROUND LUG AC INLET LINE EQUIP TRIGGER EN...

Страница 6: ...ckdoor surges coming in on the signal lines 19 CATV Coax Jacks One pair of F Connectors optimized for Cable TV Antenna or Cable Modem signal line protection 12 DC Trigger Input 3 5mm 1 8 Mini Plug jac...

Страница 7: ...s activated Switched Outlets Green LED This light indi cates the status of the Isolated Switched and High Current outlet banks When the LED is ON both out let banks are on and providing power When the...

Страница 8: ...VAC to your equipment but has the benefit of canceling any common mode noise between Line Neutral and Ground FEATURE DETAILS continued Sequential Startup Shutdown Complex audio video systems may be su...

Страница 9: ...main ON continually to provide a constant power source for programmable analog or video components A digital video recorder and VCR are two examples of components that require constant power A digital...

Страница 10: ...cable TV line Alternatively it may be used to protect the equipment plugged into the MAX 5510 Pro from backdoor surges in situations where the video signal is run to another room for a 2nd television...

Страница 11: ...ection YES Over voltage shutoff threshold Response time 137 4 VAC 10 milliseconds Under voltage shutoff threshold Response time 95 4 VAC 500 milliseconds NOISE FILTRATION Filtered Outlet Banks 55 dB 1...

Страница 12: ...outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high current delayed outlets are ON f HICURRENTOFF if the high current o...

Страница 13: ...L N currents are equalized effectively eliminating magnetic field radiation from connected power cords through current phase cancellation 1 Radiated electrical fields can still be evident but to a muc...

Страница 14: ...Transformer outlets share the 720 VA Isolation transformer for their power source The connected equipment plugged into the four outlets are drawing more than 6 Amps collectively causing the circuit br...

Страница 15: ...707 283 5901 PANAMAX the Panamax logo and MAX are registered US trademarks of Panamax ACRegenerator and SignalPerfect are trademarks of PANAMAX SIDACtor is a registered US trademark of Teccor Electro...

Страница 16: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 Email sales panamax com Web www panamax com 2004 Panamax INS0762 Rev A 12 04...

Отзывы: