Panamax M5300-EX Скачать руководство пользователя страница 2

   VOLTAGE SENSE 

TRIGGER INPUT

15 AMP CIRCUIT 

BREAKER

GROUND

LUG

MAIN POWER

120 VAC/15A

SATELLITE 1

CATV / ANT

SATELLITE

CATV / ANT 1

SATELLITE 2

CATV / ANT 2

PHONE

LAN

3 - 24VDC

LINE IN                EQUIP.             LINE IN           EQUIP.    

DELAY ON

BANK 3

HIGH CURRENT

SUB / AMP                                 RECEIVER

HD CABLE / SA

T                      HDTV / MONITOR

DIGIT

AL RADIO                              DVR

DVD                                          CD

PRE-AMP                                  AUX / VCR

BANK 2

SWITCHED

BANK 1

ALWAYS ON

POWER AND FILTRATION

BANK 1 

ALWAYS ON

BANK 2

ON 

BANK 3

ON

WIRING

OK

METER
LIGHTS

M5300-EX

Home Theater Power Conditioner

VOLTS

Power Button

Press and hold for 2 sec-
onds to turn Bank 2 and
Bank 3 outlets ON or OFF.
This switch is bypassed if
the rear panel DC Trigger
input is being used.

Power LEDs

Indicates the status of the rear panel
outlets.  LEDs for each outlet bank
will be lit when the outlets are turned
ON.  They will flash during the start-
up and shutdown process.

Circuit Breaker

Automatically opens
when the current load
is greater than 15
Amps.  Push to reset.

Ground Lug

Provides a common
grounding point for
equipment with sep-
arate ground leads.

Main Power

Must be plugged
into a properly
wired & ground-
ed 3-wire outlet

Wiring OK LED

Normally On.  Indicates
that the wall outlet is
properly grounded and
Line/Neutral polarity is
correct.

Meter Dimmer

Pushbutton control for
meter LED brightness.
Cycles between Off,
Low, Medium and High.

Unsafe Voltage Indicator

Normally Off.  Flashes to indicate that the incoming
line voltage is unsafe and the unit has disconnect-
ed the power to protect your equipment.

Convenience 
Outlet

Provides a quick con-
venient way to plug in
components such as
camcorders and video
game systems.

Outlet Bank 1 

Four always on outlets

.  Power will only

be turned off under a fault condition.
(See specifications for over-voltage and
under-voltage thresholds)  Power is
cleaned by a three-stage balanced Pi fil-
ter which also provides noise isolation
from Outlet Banks 2 and 3.

Outlet Bank 2

Four switched outlets

controlled by the

front panel Power Button or the DC Trigger
input.  Bank 2 will turn on immediately and
turn off after 10 seconds.  EMI/RFI noise fil-
tration is provided by a three-stage balanced
Pi filter which also provides noise isolation
from Outlet Banks 1 and 3.

Outlet Bank 3

Two switched, high current
outlets

controlled by the

front panel Power Button or
the DC Trigger input.  Bank 3
has a 5 second turn on delay
and turns off immediately.
The High Current outlets pro-
vide power from a low
impedance noise filtration
circuit that does not limit the
current to your equipment.
Its output is noise isolated
from all other outlet banks.    

Voltage Sense Trigger Input

3.5mm (1/8”) Mini-Plug jack.
Connect to a remote trigger device
that uses a DC output to trigger a
startup/shutdown sequence.  This
bypasses the front panel power
switch.  

Important, Please Note:

The unit needs to be plugged in,
and in the powered OFF state
before inserting the DC input trig-
ger mini-plug.

LAN Jacks

Protection circuits
for 10/100 baseT
Ethernet lines.
Incoming LAN line

MUST 

be plugged

into the 

LINE

jack.

Patch cord to the
equipment 

MUST

be plugged into
the 

EQUIP

jacks.

Phone Jacks

Protection circuits for
standard telephone or pay-
per-view lines.  Phone cir-
cuit is auto-resetting.
Incoming phone cord

MUST 

be plugged into the

LINE

jack.  Patch cords to

the equipment (satellite
receiver, digital video
recorder, telephone, etc.)

MUST

be plugged into the

EQUIP

jacks.

Satellite TV 
Coax Jacks

Bidirectional protection cir-
cuit optimized for satellite
TV signal lines.  

Do not use

for cable TV off-air anten-
nas and cable modems.

Cable TV Coax Jacks

Bidirectional protection cir-
cuit optimized for cable TV,
off-air antennas and cable
modem signal lines.  

Do not

use for Satellite TV.

Voltmeter

Digital LED voltmeter indicates incoming
line voltages between 90–140VAC.

M5300 -EX Back Panel Connection Features

M5300 -EX Front Panel Features

Note to CATV Installers:

This reminder is provided to call attention to Article 820-40 of the NEC.  That article provides specific
guidelines for proper grounding.It specifies that the cable ground shall be connected to the grounding
system of the building and as close to the point of entry as practical.

Содержание M5300-EX

Страница 1: ...atically disconnect your equipment from the power to protect equipment from damage Once the voltage returns to a safe level the MAX 5300 EX will automatically reconnect the power Protect or Disconnect...

Страница 2: ...r input Bank 2 will turn on immediately and turn off after 10 seconds EMI RFI noise fil tration is provided by a three stage balanced Pi filter which also provides noise isolation from Outlet Banks 1...

Страница 3: ...ltage 120V 60Hz Total Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Energy Dissipation 1815 Joules Peak Impulse Current 73 000 Amps Cata...

Страница 4: ...onnecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protector for surge damage The Panamax protector must show signs of surge damage or must be performing outside 10 of desig...

Страница 5: ...onectar su equipo de la corriente para proteger su equipo de da o Una vez que la corriente regresa a una tensi n segura el MAX 5300 EX autom ticamente reconectar su equipo Proteger o Desconectar CA Pr...

Страница 6: ...e o el disparador CD El Banco 2 se enceder y se apagar desp es de 10 segundos Filtraci n de ruido EMI RFI es proporcionado por un circuito toma de tres etapas filtro equilibrado Pi el cual propor cion...

Страница 7: ...260V Capacitancia 30pf approx Modos de Protecci n Met lico y Longitudinal Jacks RJ 11 Alambres Protegidos 2 alambres Patillas 4 5 Circuito de TV en Sat lite Bidireccional Si Blindado Si Nivel de Sujec...

Страница 8: ...ro de 30 d as Antes de desconec tar su sistema favor diagrame de su configu raci n porque un diagrama de su sistema se requerir como parte de sus documentos de reclamo 4 DETERMINACION DE FALLA El prot...

Страница 9: ...ne fois la tension revenue une valeur s re le MAX 5300 EX r tablit automatique ment l alimentation Protection contre les surtensions c a Protect or Disconnect En cas de surtension la tension de sortie...

Страница 10: ...an e tandis que l arr t se fait apr s 10 secondes Le fil trage du bruit EMI RFI est assur par un fil tre en pi quilibr trois tages qui sert galement d isolation acoustique des bancs de sorties 1 et 3...

Страница 11: ...initialisation Oui Seuil de calage 260V Capacit 30pf env Modes de suppression M tallique et longitudinal Prises RJ 11 Fils prot g s 2 fils broches 4 et 5 Circuit pour r ception t l par satellite Bidir...

Страница 12: ...autorisation de retour Panamax vous postera une trousse de demande de r glement que vous devrez remplir et retourner dans les 30 jours Un sch ma de c blage de votre syst me sera exig Assurez vous de n...

Отзывы: