One telephone patch cord

Product warranty (see page 4)

Two coaxial cables

M5100-PM Specifications
AC Power

Line Voltage:...................................................................120V, 60Hz
Total Current Capacity:..............................................................15 A

Protection Modes:.......................................................L-N, L-G, N-G
Initial Clamping Level:..............................................................200V
Energy Dissipation:........................................................1875 Joules
Peak Impulse Current:.................................................90,000 Amps
Catastrophic Surge Circuit:..........................................................Yes
Thermal Fusing:..........................................................................Yes

Over-voltage shutoff:.............................................142 VAC ± 5 VAC
Under-voltage shutoff:.............................................90 VAC ± 2 VAC

EMI/RFI Noise Filtration
Banks 1 & 2:..............................................80 db, 100 KHz - 2 MHz
Bank 3, High Current Outlets:....................60 db, 100 KHz - 2 MHz

DC Trigger Input

Jacks:................................................3.5mm (1/8”) mono mini-plug
Voltage and Polarity:.................................3 - 24V DC, bidirectional
Current Requirement:............................4.6 mA @3V, 58 mA @24V

LAN Circuits

Clamping Level:.........................................................................50V
Jacks:.....................................................................................RJ-45
Wires Protected:...................................................................8-Wires

USB Circuit

Jacks......................................................................................USB-A
Power Delivery...................................................... 500 mA @ 5VDC

Telephone Circuit

Fuseless/Auto-resetting:.............................................................Yes
Clamping Level:........................................................................260V
Capacitance:...............................................................30pf (approx.)
Suppression Modes:.....................................Metallic & Longitudinal
Jacks:......................................................................................RJ-11
Wires Protected:..................................................2-Wire, Pins 4 & 5

Cable and Satellite Circuits

HD 1080 i/p Ready ..................................................................Yes
Bi-directional........................................................................... Yes
Shielded...................................................................................Yes
Clamping Level........................................................................75V
Frequency Range..................................................0MHz - 2.2 GHz
Insertion Loss...................................................................< 0.5 dB
Connections.............................................Female “F”, Gold Plated

M5100-EX Specifications

Contacting Panamax

Contents

© 2009  Panamax, Inc.  Panamax, MAX and the Panamax logo are registered US trademarks of Panamax.  Protect or Disconnect and SignalPerfect are trademarks of Panamax, Inc. 

SIDACtor is a registered US trademark of Teccor Electronics, Inc. Foreign Language Version produced by International Contact, Inc.

Specifications are subject to changes due to product upgrades and improvements.

3

Voltage Protection Rating (UL1449 3rd Edition, 3,000A): ...................500V

Содержание M5100-PM

Страница 1: ...e magnitude of the surge is greater than the capacity of the surge protection compo nents the MAX 5100 PM s Protect or Disconnect Circuitry will disconnect your equipment in order to protect it The MA...

Страница 2: ...r to protect your equip ment M5100 PM Back Panel Connection Features M5100 PM Front Panel Features M5100 PM VOLTS LINEAR FILTER LINEAR FILTER HIGH CURRENT WIRING OK BANK 1 BANK 2 BANK 3 Bank 1 Indicat...

Страница 3: ...t Requirement 4 6 mA 3V 58 mA 24V LAN Circuits Clamping Level 50V Jacks RJ 45 Wires Protected 8 Wires USB Circuit Jacks USB A Power Delivery 500 mA 5VDC Telephone Circuit Fuseless Auto resetting Yes C...

Страница 4: ...ion diagram of your system will be required as part of the claim kit Be sure to note its configuration before disconnecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protecto...

Страница 5: ...PM es capaz de soportar sin da o alguno transitorios de 20 000 A muy por encima de los 3 000 Amperios que exige el requisito UL Si la magnitud del sobrevoltaje supera la capacidad de los componentes...

Страница 6: ...ente ENCENDIDA esta luz se enciende cuando hay energ a en los recept cu los de la Regleta 1 Orejeta de toma de tierra Proporciona un punto com n de toma de tierra para los equipos que llevan la conexi...

Страница 7: ...Voltaje y polaridad 3 24 Vcc bidireccional Corriente necesaria 4 6 mA 3V 58 mA 24V Circuitos de red local Nivel de fijaci n 50 V Conectores RJ 45 Hilos protegidos Los 8 hilos Circuito USB Conectores U...

Страница 8: ...e deber rellenar y devolvernos en un plazo de 30 d as Dentro de la documentaci n de reclamaci n se le pedir que incluya una diagra ma de conexi n de su sistema No olvide anotar esta configuraci n ante...

Страница 9: ...a norme des laboratoires UL qui sp cifient une r sistance une surtension de seulement 3000 amp res Si la surtension d passe la capacit de pro tection du MAX 5100 PM ses circuits Protect or Disconnect...

Страница 10: ...M5100 PM VOLTS LINEAR FILTER LINEAR FILTER HIGH CURRENT WIRING OK BANK 1 BANK 2 BANK 3 T moin du bloc prises 1 Allum en conditions normales quand les prises du bloc 1 re oivent une alimentation Cosse...

Страница 11: ...Tension et polarit 3 24V C C bidirectionnel Caract ristiques du courant 4 6 mA 3V 58 mA 24V Circuits LAN Niveau de blocage 50V Connecteurs RJ 45 Fils prot g s 8 fils Circuit USB Connecteurs USB A Alim...

Страница 12: ...dommag s lors de la demande d autorisation de retour d article Panamax vous enverra un dossier de demande remplir et renvoyer dans les 30 jours Il vous faudra joindre un diagramme de connexion de votr...

Отзывы: