background image

 M4300-PM BACK PANEL FEATURES

1. Circuit Breaker: 

Automatically opens

when the current load

is greater than 15

Amps. Push to reset.

5. Universal Coaxial  

Connectors

2 pairs of bidirectional 

protection circuits optimized for 

satellite, cable, and antenna 

TV signal lines.

3. Outlet Bank 1 

Four switched outlets with linear filtration technol

-

ogy (LiFT) controlled by the front panel Power 

Button. 

LiFT

 EMI/RFI noise filtration is provided by a single 

stage linear filter circuit which also provides noise 

isolation from all four outlets in Bank 2.

2. Outlet Bank 2

Four switched, high-current outlets controlled by 

the front panel Power Button. 

The High Current outlet provides power from a low 

impedance noise filtration circuit that does not limit 

the current to your equipment. Its output is noise 

isolated from Outlet Bank 1.

6. Main Power

Must be plugged into a 

properly wired & grounded 

3-wire outlet

.

4. LAN Jacks

Protection circuits for 10/100 baseT 

Ethernet lines. Incoming LAN line MUST 

be plugged into the LINE jack. Patch cord 

to the equipment MUST be plugged into 

the EQUIP jacks.  8 wire protection, 50V 

clamping.

7. Ground Lug: 

Provides a common grounding 

point for equipment with separate 

ground leads

8. Phone Jacks

Protection circuits for standard telephone 

or pay-per-view lines. Phone circuit is 

autoresetting. Incoming phone cord MUST 

be plugged into the LINE jack. Patch cords 

to the equipment (satellite receive

r, digital 

video recorde

r, telephone, etc.) MUST be 

plugged into the EQUIP jacks.

M4300-PM SPECIFICATIONS

UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

General________________________________________________________________

Dimensions...................................17 in. W x 7.75 in. D x 1.75 in H, (2.125 in. Including feet)
Weight..........................................................................................................................6.5 lbs.

AC Power_______________________________________________________________

Line Voltage..........................................................................................................120V, 60Hz
Isolated Banks......................................................................................................................2
Voltage Regulation..............................................................................................................No
Total Outlets...............................................................................................................9 outlets
Always-On Outlets.....................................................................................................0 outlets
Switched Outlets........................................................................................................9 outlets
High Current Outlets..................................................................................................4 outlets  
Total Current Capacity........................................................................................15 A (1800W)

Protection Modes..............................................................................................L-N, L-G, N-G

Initial Clamping Level.........................................................................200V Peak, 141V RMS

Energy Dissipation...............................................................................................1675 Joules
Peak Impulse Current........................................................................................60,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:................................................................................................................Yes

Auto-resetting Over-voltage shuto

ff............................................................142 VAC ± 8 VAC

Auto-resetting Under-voltage shuto

ff............................................................86 VAC ± 6 VAC

EMI/RFI Noise Filtration___________________________________________________

Bank 1, Linear Filtration Switched Outlets...........................Up to -80 db (100 KHz – 2 MHz)
Bank 2, High Current Switched Outlets...............................Up to -55 db (100 KHz – 2 MHz)  

LAN Protection___________________________________________________________

Clamping Level..........................................................................................................60 ± 5V

Compatibility............................................................................................................10/100bT
Jacks............................................................................................................................RJ-45  
Wires Protected:........................................................................................................8-Wires

 

USB Circuit_____________________________________________________________

Jacks...........................................................................................................................USB-A  

Power Deliver

y.............................................................................................500 mA @5VDC

Telco Protection_________________________________________________________

Fuseless/Auto-resetting.................................................................................................. Yes

Clamping Level............................................................................................................. 260V

Capacitance....................................................................................................30pf (approx.)
Suppression Modes.......................................................................... Metallic & Longitudinal
Connectors...................................................................................................................RJ-11
Lines Protected.........................................................................................2-Wire, Pins 4 & 5

Universal Coax Protection_________________________________________________

HD 1080 i/p Ready...........................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes

Clamping Level................................................................................................................75V

Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss............................................................................................................< 0.5 dB
Connectors.......................................................................................Female “F”, Gold Plated

MODEL M4300-PM

MASTER CARTON

UNIT CARTON

         Dimensions                           Weight                      Dimensions                  Weight                     UPC                    Qty             Dimensions              Weight                        UPC

  

             

17” x 7.75” x 1.75”                    6.5 lbs                19.5” x 12” x 4.625”           8 Lbs              0 50616 00818 1            2        20” x 12.75” x 10.75”     17.5 Lbs          5 00 50616 00818 6

       

2.125

” H with feet                                                                                                                                                                            

1690 Corporate Circle, Petaluma, CA. 94954  • 800-472-5555  •  707-283-5900  • Fax 707-283-5901  • ww

w.panamax.com

© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax

Design and specifications are subject to change due to product upgrades and improvements.

L586 REV D  12/09

Voltage Protection Rating (UL1449 3rd Edition, 3,000A)............................................... 500V

Отзывы: