Operating the room station. 
 
Paging

.

  General paging throughout all stations, except the Door Station, 

can be performed by pressing and holding the

  TALK button while 

talking and releasing to hear a reply.  To answer the intercom page, the 
responder presses the 

 TALK button once to respond to the page and 

can then reply hands-free.  The caller must hold the TALK to talk and 
release to listen. 

Pressing the 

 CANCEL button will end the conversation.  If cancel is not 

pressed, the system will auto-cancel after 30 seconds. 
 

Mute

.

  Any Room Station can be muted or locked-out for privacy.  Pressing 

and holding 

 CANCEL first 

then

 

 DOOR Release button, will cause 

that station to be muted.  When a station is muted, it will not be able to hear 
the door chime, a monitored station or intercom page.  Mute can be 
cancelled by pressing the cancel button on that station. 
 

Monitor

.

  Any Room Station can be monitored by other Room Stations. 

Pressing and holding the

  CANCEL first and 

then

 

 TALK button 

together on the Room Station will initiate monitoring mode.  Monitoring can 

be cancelled by pressing the 

 Cancel button of the monitored room 

station.  Only one Room Station can be monitored at any one time. 

 

LEDs

.

 

The Panacom Q916 is equipped with red and green LEDs to 

indicate system mode and status.  The table below describes the functions 
of each LED indicator. 

 
Volume Control.

  All Stations have individual volume control located on 

the side of each room station.  Adjusting the volume will alter the volume of 
both intercom sound and door chime for that station only. 

Action/Status 

Red LED 

Green LED 

Blue LED 

System standby or default. 

Solid 

 

 

Door Station in standby or activated mode 

 

 

Solid 

Room Station responding to Door Station 

 

Solid 

 

Room Station initial intercom page 

Flashing 

 

 

Answering a Room Station intercom page 

 

Solid 

 

Room Station in Mute mode 

Solid 

Solid 

 

Room Station being monitored 

 

Flashing 

 

Room Station listening to monitored station 

 

Solid 

 

Содержание Q916

Страница 1: ...om power supply PANQ916KG Kit Grey door silver master room power supply PANQ916K SP Stainless steel door plate Kit Door silver master room power supply PANQ916K GP Gold door plate Kit Door silver master room power supply PANQ916M Silver master room station PANQ916S Silver room station PANQ916DG Grey door station PANQ916DS Silver door station PANQ916MUS Music module ...

Страница 2: ...ry 12V DC output to trigger external devices Listen to background music from an auxiliary input music module Music will mute when door bell is activated Technical Specifications Power Requirements 16V AC 1 5Amp Power Consumption per unit 25mA idle 55mA busy 500mA with door latch powered Operating Temperature 0 to 50 C System Cable 3 pair solid core twisted cable between stations shielded preferred...

Страница 3: ...3 Installation Before installing the system refer to ID settings on page 7 ...

Страница 4: ... looped via Room Stations back to the Master Station All wiring should be kept as short as possible Exceeding 200m of total wiring may degrade communication quality Caution To avoid electrical interference be careful not to run intercom cables near mains cable or through the same ducting or conduits as mains cable Caution To avoid audio feedback units should be installed at least 5 metres apart no...

Страница 5: ...ayer Music can be muted by pressing CANCEL button Press CANCEL button again to un mute NOTE The door station is designed to be weather resistant against normal weather conditions It is not waterproof We strongly recommend the door station be installed as best as possible to avoid water from getting into the unit Do not spray or hose water directly at the door station THIS WILL VOID WARRANTY If mou...

Страница 6: ... the surface mount base to the wall Install Station onto the base with screw provided Replace the front cover onto the station Refer to diagram below Recess Mounting Instruction A single wall mounting clip not included is required for flush mounting Cut out the wall board to 96mm H x 65mm W by using the back cover as a template Recess the station into the wall and fasten the station onto the wall ...

Страница 7: ...mum number of internal room stations allowed is sixteen Door Stations If more than one Door Station is installed set the second secondary or back door door station to its correct ID setting F The first primary or front door Door station E can operate the door latch at all times The secondary door station can only operate an electric latch when it is in communication mode Turning the dial with exce...

Страница 8: ...nd releasing the talk button to listen Pressing the CANCEL button will end conversation If cancel is not pressed the system will auto cancel after 30 seconds If a door latch is installed pressing the unlock DOOR button momentarily will open or unlock the door The volume control is located behind the metal cover just above the cancel button Adjusting the volume will alter both intercom and door chi...

Страница 9: ...om Station can be monitored by other Room Stations Pressing and holding the CANCEL first and then TALK button together on the Room Station will initiate monitoring mode Monitoring can be cancelled by pressing the Cancel button of the monitored room station Only one Room Station can be monitored at any one time LEDs The Panacom Q916 is equipped with red and green LEDs to indicate system mode and st...

Страница 10: ...nish Dear Installer Thank you for your continual support Please leave this manual with the home owner Installed By Date of installation Warranty PSA Products warrants our products against defects faulty workmanship and materials for a period of 12 months This warranty does not cover damage or failure caused by Acts of God abuse misuse faulty installation improper maintenance any alterations or rep...

Страница 11: ...o Intercoms Audio Intercoms Wireless Intercoms Security Alarm Systems CCTV cameras and DVR Systems Access Control Systems Apartment Intercom Systems Access Control Smoke Alarms and Accessories Fire Panels and Detectors Fire Extinguisher and Blankets ...

Страница 12: ...ther Quality Product by PSA Products Pty Ltd 17 Millicent Street Burwood Victoria 3125 Australia Tel 1300 772 776 PSAPRODUCTS Fax 03 9888 9993 e mail enquiry psaproducts com au web site www psaproducts com au ...

Отзывы: