2 ADDITIONAL INFORMATION 

2.1 LED Indications 

 

 
LED

 

State

 

Indication

 

Additional Information

 

Power

 

solid green  unit is operational  If the Power LED is not illuminated, it is 

unlikely that the SPEED-DSL 9.2 is 
receiving power and therefore none of the 

LEDs will be illuminated. 

 

pulsing 

green 

G.SHDSL 

connection is 

established and 

active 

Traffic is flowing. 

solid green  problematic 

G.SHDSL 

connection 

A connection exists but there is indication 

of a problem with the G.SHDSL line. 

SDSL Link (Lnk) 

Ports 1 - 4

 

no 

illumination 

no G.SHDSL 

connection 

See NOTE on following page.

 

 

flashing 

amber 

G.SHDSL activity 

The SPEED-DSL 9.2 is receiving data. 

solid amber  heavy Rx traffic 

The SPEED-DSL 9.2 is receiving large 

amounts of data. 

SDSL Data 

Reception (Rx) 

Ports 1 - 4

 

no 
illumination 

no activity 

A G.SHDSL link may exist but the SPEED-
DSL 9.2 is not receiving any data. 

 

flashing 

amber 

G.SHDSL activity 

The SPEED-DSL 9.2 is transmitting data. 

solid amber  heavy Tx traffic 

The SPEED-DSL 9.2 is transmitting large 

amounts of data. 

SDSL Data 

Transmission (Tx) 

Ports 1 - 4

 

no 

illumination 

no activity 

A G.SHDSL link may exist but the SPEED-

DSL 9.2 is not transmitting any data. 

 

solid green  100 Mbps Ethernet 

connection is 

established 

If the Ethernet 100 LED is illuminated, the 

Ethernet Lnk LED will also be illuminated. 

 

See NOTE below.

 

100 Mbps 

Ethernet Link 

(100)

 

no 

illumination 

no 100 Mbps 

Ethernet 

connection 

If the Ethernet 100 LED remains unlit but 

the Ethernet Lnk LED is illuminated then a 

connection has been established at 10 

Mbps rather than 100 Mbps. 

 

pulsing 

amber 

standard operation  Traffic is flowing without any problems 

10/100 Ethernet 

Activity (Act)

 

solid amber  heavy traffic 

A solid amber Ethernet Act LED can also 

signify a lost G.SHDSL connection; 

see 

NOTE below

Содержание Speed-DSL 9.2

Страница 1: ...Speed DSL 9 2 Ethernet connection over 8 wires up to 9 2 Mbit s Manual 220 0000098 220 0000098 ...

Страница 2: ...ts may not have been taken into account Pan Dacom Direkt does not assume liability for print errors contained in this manual or other inaccuracies Pan Dacom Direkt explicitly points out that this manual only contains a general description of technical processes and notes and that their implementation as described is not necessarily sensible in every individual case In case of doubt it is essential...

Страница 3: ... another to provide eight bandwidth options for the four G SHDSL ports as a group bandwidth cannot be configured individually for the G SHDSL ports NOTE Configuration switches 1 3 are used for G SHDSL bandwidth configuration on the SPEED DSL 9 2 P ONLY The SPEED DSL 9 2etermines bandwidth via communication with its partner G SHDSL provider equipment Switches 4 8 are not currently used on the SPEED...

Страница 4: ... 4 1 Loop Bonded Connection Using two three or four G SHDSL lines for one network connection loop bonding will net two three or four times the speed and data passing capability as a single G SHDSL connection Multiple G SHDSL lines used for one connection can also be considered as backup for each other should one or more of the lines become disabled NOTE A SPEED DSL 9 2 must be connected with equip...

Страница 5: ...ider equipment Likewise a single line connection can also be established between an SPEED DSL 9 2 P and G SHDSL subscriber units Verify your connection the G SHDSL LED corresponding to the connected port G SHDSL 1 4 will flash green to indicate the connection is established and operational ...

Страница 6: ...nks has been established 1 5 1 Duplex Mode The 10 100 Ethernet port auto negotiates speed and duplex mode in accordance with the remote equipment to which it s connected Ethernet speed and duplex mode configurations cannot be hard set on the SPEED DSL 9 2 For the best connection results the remote device PC hub switch etc should be set to auto negotiate speed and duplex mode as well If the remote ...

Страница 7: ...SPEED DSL 9 2 SPEED DSL 9 2 22 10 2004 page 7 10 100 Ethernet RJ45 Pinout PIN CONNECTION 1 Rx 2 Rx 3 Tx 4 not used 5 not used 6 Tx 7 not used 8 not used ...

Страница 8: ...o illumination no activity A G SHDSL link may exist but the SPEED DSL 9 2 is not receiving any data flashing amber G SHDSL activity The SPEED DSL 9 2 is transmitting data solid amber heavy Tx traffic The SPEED DSL 9 2 is transmitting large amounts of data SDSL Data Transmission Tx Ports 1 4 no illumination no activity A G SHDSL link may exist but the SPEED DSL 9 2 is not transmitting any data soli...

Страница 9: ...SPEED DSL 9 2 SPEED DSL 9 2 22 10 2004 page 9 no illumination no activity Either there is no Ethernet link or a link exists but there is no activity ...

Страница 10: ...The Ethernet 100 and Act LEDs will remain unlit by default A pulsing LED blinks steadily at a rate of once per second A flashing LED blinks at a more rapid less constant rate NOTE Upon start up the Ethernet link will remain disabled as indicated by solid illumination of the Ethernet 100 Act and Lnk LEDs until at least one of the four G SHDSL connections has been established Likewise if one or more...

Страница 11: ...dio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by the manufacture...

Страница 12: ...5880 GS Ost Germania Bogen Multimedia Center 12099 Berlin Tel 030 7508 3500 Fax 030 7508 3535 GS Süd Inselkammerstraße 10 82008 Unterhaching Tel 089 614478 0 Fax 089 61447850 GS Südwest Kurze Straße 40 70794 Filderstadt Tel 0711 7705506 0 Fax 0711 77055070 GS Mitte Zentrale Robert Bosch Straße 32 63303 Dreieich Tel 06103 932 0 Fax 06103 932400 Technical Hotline 06103 932 100 Fax 06103 932 413 disp...

Отзывы: