APPENDIX A:
SPECIFICATIONS
Frequency Generation & Control:
•
1 - 30 MHz
•
Source Impedance: 50-Ohms
•
Stability: +/- 50 ppm
•
Spectral Purity: Harmonics down >-35 dB beyond 30 MHz
•
Step Size: User configurable increments of 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz
Usable Measurement Range:
•
SWR: 1.0 to 9.9
•
Impedance: approx. 5 to 600 ohms
RF Output:
•
2 Volts p-p (typical)
Power Supply:
•
External: 9-to-16.0 Volts DC
•
Internal: Eight AA-cells, alkaline or NiMH
•
Current Requirements: 200 ma (typical)
User Interface:
•
Pushbuttons (5): “Mode”, “Band”, “Scan”, “Setup”, “On/Off”
•
Rotary Encoder: “Tuning”, 24-position/rotation, smooth/detentless operation
•
LED: “Busy”
•
2 line x 16 character LCD display, with optional backlight under software control, configured in
SETUP menus. Backlight may be configured to turn off after user-set period of inactivity. If enabled,
backlight turns on again with any of the controls are touched.
Power Control:
•
Power applied by press-and-hold of On/Off momentary contact pushbutton
•
Instrument turns itself off after preset period of inactivity, configured in SETUP menus
Connectors:
•
External Power: 2.1mm coaxial power plug (center pin positive)
•
RF Out: BNC
•
Serial Port: RS232 (DB9F)
Environmental
•
Temperature: 0-70C
•
Humidity: 0-100% RH