background image

OPERATION 

CHILD LOCK MODE 

A child lock mode is available to prevent children interfering with and/or inadvertent operation of the heater controls. 

To activate child lock mode:

 

Press and hold down the ▲ and ▼ buttons simultaneously for three seconds then 

release both buttons. The child lock LED will illuminate green to indicate that the heater is in child lock mode. 

To deactivate child lock mode:

 

Press and hold down the ▲ and ▼ buttons simultaneously for three seconds then 

release both buttons. The child lock LED will extinguish to indicate that the heater is no longer in child lock mode. 

Note: If the burner is operating and child lock mode is activated, the ‘Power’ button can still be pressed and released 
to turn the heater OFF only. 
 

FILTER LIGHT 

The filter light will illuminate and flash if the filter is blocked and requires cleaning (refer to “Regular Care” on page 7). 
 

HUMIDIFIER TRAY 

The heater has a humidifier tray located behind the lower front cover. The humidifier tray can be filled with water to 
raise the humidity level in the room for extra comfort if required (refer to "Humidifier Tray Removal" on page 7). 

 
VERTICAL LOUVRE ADJUSTMENT 

The vertical louvers on the heaters front louvre can be adjusted to direct air flow in the required direction by pushing 
the vertical section to the left or the right. Note: The horizontal louvres are fixed and cannot be adjusted. 

  
SAFETY DEVICES 

Various automatic safety devices are fitted to the heater to provide safe operation. For more information refer to 'How 
Your Heater Works' on page 4.  
 

CENTRAL CONTROL – COMMERCIAL MODELS ONLY 

PRS-250CN and PRS-250CL commercial models can be controlled by an external central control system, such as a 
time clock or BMS, which can be programmed to turn the heater (or group of heaters) ON or OFF at scheduled times. 
For information on using a central control system refer to "Central Control Connection & Operation – Commercial 
Models Only" on page 20. 
 

12 

 

Содержание PRS-150L

Страница 1: ...sealed flue kit Failure to install a genuine Paloma room sealed flue kit will result in a potentially unsafe installation and the heater warranty will become null and void For installation of the flu...

Страница 2: ...or a responsible officer DO NOT leave this guide inside the heater cover or behind the heater as it may interfere with the safe operation of the space heater or ignite when the heater is turned on Hea...

Страница 3: ...2 Vertical Louvre Adjustment 12 Safety Devices 12 Central Control Commercial Models Only 12 INSTALLATION 13 Heater Location Clearances 13 Minimum Maximum Room Sizes 14 Heater Installation Procedure 14...

Страница 4: ...burner is controlled by an electronic controller thermostat which senses the room air temperature The following automatic safety controls are fitted to the heater Filter Clean Warning Device When the...

Страница 5: ...r to Heater Clearances table on page 13 DO turn the heater OFF at the control panel when unattended or not in use Do not turn the heater off by switching off at the power point The power point may be...

Страница 6: ...hich the heater is installed too large Do you have the correct size heater for your room size Refer to Heater Maximum Room Size on page 14 Is the area subjected to drafts Ensure windows and doors are...

Страница 7: ...moving air filter To remove the air filter The air filter is located on the top rear of the heater and is removed by grasping the handle on top of the filter and lifting upwards To replace the air fil...

Страница 8: ...mell gas do not attempt to turn on the heater Switch on the electrical supply at the power point The heater will perform a self check routine After the self check routine expires the heater can be tur...

Страница 9: ...isplay and the Clock LED and AM or PM will illuminate green 2 Press and hold down the or button The display will change in 1 minute increments until the next hour is reached at which time the display...

Страница 10: ...d the Power button LED will change from green to red upon successful ignition When the timers programmed OFF time is reached the burner will turn off and the timer button LED will stop flashing but re...

Страница 11: ...h and the burner will turn off provided the current time is not within the selected timers programmed on period including pre heat period AUTO OFF TIMER OPERATION The Auto Off Timer can be activated s...

Страница 12: ...ge 7 HUMIDIFIER TRAY The heater has a humidifier tray located behind the lower front cover The humidifier tray can be filled with water to raise the humidity level in the room for extra comfort if req...

Страница 13: ...the flue kit refer to the installation instructions supplied with the flue kit Warning Ensure that the gas specified on the heater rating label matches the gas supply Using a different gas type may c...

Страница 14: ...Gas Space Heaters should not to be installed in a room larger than the specified maximum room size Although the heater can be installed in a room larger than the specified maximum room size the maximu...

Страница 15: ...LED FLUE KIT IS INSTALLED The following information is provided here as a guide only for installation of the flue kit refer to the installation instructions supplied with the flue kit The diagram belo...

Страница 16: ...in AS NZS 5601 1 must be used The location of the flue terminal must comply with the requirements of AS NZS 5601 1 Clause 6 9 and figure 6 2 which are summarised here as a guide only It is the install...

Страница 17: ...1500 500 Appliances over 250 MJ h input 1500 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower refer to note 2 1500 1000 n...

Страница 18: ...result on initial start up An isolation valve and disconnection union must be installed to allow servicing and removal of the heater Refer to AS NZS 5601 or AS NZS 5601 1 for the correct pipe sizing W...

Страница 19: ...o a 240V AC 50 Hz M E N multiple earthed neutral mains power supply The GPO should be located in an accessible position beside the heater The GPO must be located within 1200 mm from the left hand side...

Страница 20: ...ure adjustment and buttons Economy button and on off operation Power button will be disabled Note If a disabled button is pressed whilst the heater is in central control mode the Central Control LED w...

Страница 21: ...to Manifold Assembly Connections diagram above 1 Lubricate manifold assembly exhaust connection internal o ring with silicone grease supplied with flue kit 2 Push heater telescopic exhaust tube into...

Страница 22: ...ush heater air intake hose over manifold assembly air intake connection until recess inside air intake hose connector is located over flange on manifold assembly air intake connection 2 Secure connect...

Страница 23: ...erfloor Installations Item Description Quantity A Top Cover 1 B RH Side Cover 1 C LH Side Cover 1 D Heater Side Replacement Brackets 2 E Screws 8g X 14 8 Note Use wall brackets and wall bracket screws...

Страница 24: ...seal flue pipe to manifold assembly when performing step 2 or 4 of the following procedure Procedure 1 Remove two lower brackets on rear of heater and replace with brackets supplied in Extra Wide Back...

Страница 25: ...height adjustable by rotating in a clockwise or anticlockwise direction to facilitate levelling and stabilisation of the heater adjust feet height if required 7 Perform a gas inlet pressure test at t...

Страница 26: ...ultaneously depressing tabs located on bottom of heater sides and pulling lower front panel away from heater 5 Remove two screws retaining front panel screws are located on bottom corners of front pan...

Страница 27: ...ulling louvre away from heater 4 Remove lower front panel by simultaneously depressing tabs located on bottom of heater sides and pulling lower front panel away from heater 5 Remove two screws retaini...

Страница 28: ...tures and any burner gas pressure adjustments made will be automatically saved 15 Turn heater off and replace gas valve test point screw and washer and inner case test point screw and washer 16 Operat...

Страница 29: ...for 10 minutes 24 Power switch failure faulty control panel 31 Room temperature thermistor abnormal open circuit or closed circuit 33 Overheat thermistor abnormal open circuit or closed circuit 34 Ov...

Страница 30: ...o ensure they are sound and firmly connected 6 Check flue system ensure all visible flue components are sound and that the flue system including the flue terminal is not obstructed or blocked in any w...

Страница 31: ...r mm 1 6 1 15 1 6 1 15 Pilot burner injector orifice diameter mm N A Temperature settings 16 26 C selectable in 1 C increments Ignition Continuous direct spark PERFORMANCE PRS 150N PRS 150L PRS 250N P...

Страница 32: ...This page is intentionally blank 32...

Страница 33: ...This page is intentionally blank 33...

Страница 34: ...This page is intentionally blank 34...

Страница 35: ...responsibility In other words the cost of dismantling or removing cupboards doors or walls and the cost of any special equipment to bring the space heater to floor or ground level or to a serviceable...

Страница 36: ...the defect and in any event within the applicable warranty period 4 2 You are not entitled to make a claim under this warranty if your space heater a Does not have its original serial numbers or rati...

Отзывы: