Before you begin ensure that the gas hose  is  connected to your bayonet gas point and electrical  cord is 
plugged in correctly. 

 

START UP – TURNING HEATER ON 

 

 

Press and release the 

ON/OFF

 Button once to start the heater and the operation light (green)  will light 

up.  

 

After a short delay the combustion light (red) will light up,  this indicates proper  ignition has been 
achieved and the burner is on. 

 

Set temperature and room temperature are displayed on the screen. 

 

Note:  When the 

ON/OFF

  light is glowing green the heater can be switched on by pressing the Remote 

Control button. 

 

TURNING HEATER OFF 

 

 

The appliance can be turned off by pressing and releasing the 

ON/OFF

  button.  The green (or red) 

ON/OFF

 operation LED will immediately extinguish and the digital display will revert to the time (if set). 

Then press the OFF button on Remote Controller. 

 

After the heater is turned off the convection  fan will continue to operate for up to 4 minutes. This is to 
lower the temperatures inside the heater and is normal. 

 

Do not unplug the heater while the fan is still operating. 

 

Important Information: 

 

When using the heater for the first time or after long periods of disuse, ignition may not  occur the first 
time it is operated as there may be air within the pipes. 

 

The unit may make noises after igniting or extinguishing the heater. This is due to expansion and 
contraction of the heater components and is normal. 

 

If the heater fails to light, repeat the procedure after first pressing the 

ON/OFF

 button to turn the unit off. 

 

Do not start then stop immediately. This may cause the heater to overheat or the filter light to come on. 

 

The economy operation will not function if the set temperature reaches a temperature in excess of the 
room temperature. 

 

For safety reasons the heater will automatically stop after 8 hours of continuous operation.  

 

 

Operating Instructions 

Содержание PJC-W18FR

Страница 1: ...Australian Standard for Gas Appliance Installations AS NZS5601 1 2010 d Any other relevant Statutory Regulation e Manufacturer s installation instructions 3 This appliance must be serviced by a quali...

Страница 2: ...2 Operating Instructions Start Up 14 Turning Heater Off 14 Automatic Economy Operation 15 Room Temp Adjustment 15 Timer Over ride Function 16 Remote Control Operation 16 Setting Clock 17 Programming T...

Страница 3: ...rying the heater Warning Label Rating Plate Shows model No Gas Type Month of Manufacture Warm Air Outlet Warm air is discharged Louvres Air Filter 1 Prevents dust entering the appliance Gas Hose Elect...

Страница 4: ...e correctly fitted 3 Replace access panel and gently push into position TIMER1 BUTTON TIMER2 BUTTON TEMPERATURE ADJUSTMENT BUTTON OVER RIDE BUTTON CHILD LOCK LIGHT ON OFF BUTTON FILTER LIGHT SET TIMES...

Страница 5: ...e heater Low Emission Technology Class 1 Appliance AS4553 2008 Less than half the emissions of the Australian Standard Energy efficient 7 stage modulating gas valve Manufactured in Japan Safety Device...

Страница 6: ...Minimum Room Sizing Cu M 62 5 45 NG kPa 0 86 0 47 LPG kPa 2 0 1 2 NG kPa 0 13 0 13 LPG kPa 0 3 0 3 NG mm 2 4 2 4 LPG mm 1 45 1 45 Number of Injectors 1 1 Temperature Settings 16 C to 26 C 16 C to 26...

Страница 7: ...pecified minimum room size requirements as the heater may shut down due to oxygen depletion showing Error Code 12 refer page 24 4 A dedicated 240V Earthed 10 Amp power point must be used with this hea...

Страница 8: ...s injury or death in the most extreme situations Caution indicates a potentially hazardous situation which if not avoided may result in minor injury If a gas leak is detected Do not turn power switche...

Страница 9: ...terial near this appliance It may result in a fire Do not post or allow children to post articles such as paper cloth or any other foreign material into the louvres or air inlet of the heater Do not b...

Страница 10: ...ded clearances are maintained at all times This heater is designed for use in a single family domestic dwelling for the purpose of room heating Its use in an application other than this may shorten it...

Страница 11: ...fined space E g fireplace Do not install in a bedroom bathroom combined living sleeping areas toilets sauna or hallways Do not install where flammable materials are likely to come into contact with th...

Страница 12: ...o flammable materials in the vicinity of the heater 2 Air filter is fitting correctly and is not dirty 3 The hose is correctly connected without kinking or twisting 4 There is no damage to the electri...

Страница 13: ...and pull upward Do not hold and pull strongly It may cause the air filter to break REFIT THE FILTER 1 Hold the upper side of the Air Filter 1 and place the filter onto the notch 2 Tighten the screw Se...

Страница 14: ...ote Controller After the heater is turned off the convection fan will continue to operate for up to 4 minutes This is to lower the temperatures inside the heater and is normal Do not unplug the heater...

Страница 15: ...ng or lowering the temperature selection buttons For Eg Select 22 Degrees C as your desired temperature and this temperature is then memorised into the control system SET temperature selection can ran...

Страница 16: ...ting outside a timer programmed time period burner off the timer may be over ridden and the heater turned on by pressing and releasing the OVERRIDE button once The OVERIRDE LED will illuminate the tim...

Страница 17: ...me will appear on the digital display Adjust the time To adjust the time of day press the down or up button until the correct time is reached Example To set clock for 11 12am 1 Adjust the hour Keep pr...

Страница 18: ...on time is displayed on the screen Adjust TIMER 1 ON or start up time as required To set the TIMER 1 ON time press the down or up button until the correct time is reached Example To set the TIMER 1 ON...

Страница 19: ...e adjustment button until 8 10PM is displayed Press and release SET TIMES button once TIMER 2 OFF LED light flashes and TIMER 2 off time is displayed on the screen Adjust TIMER 2 OFF time as required...

Страница 20: ...will turn on as the ON OFF button is in the ON position 4 It should be noted that the TIMER times are not required to be programmed and the timer programming mode can be exited at any stage by pressi...

Страница 21: ...r both by pressing the TIMER 1 and or TIMER 2 buttons Selected TIMER s ON OFF lights will glow The TIMER operation is not set and will not function if the TIMER s ON and OFF lights are not glowing If...

Страница 22: ...will not be selected The timer settings will continue to operate if they are not cancelled CHILD LOCK This heater has a CHILD LOCK function which prevents accidental operation as well as children inte...

Страница 23: ...ing after the heater is sw itched off It stops after the temperature inside the heater has cooled No action required The heater creaks at the time of lighting or sw itching off The sound is caused by...

Страница 24: ...tly or install ventilation points and operate again If problem persists call for service Insufficient ventilation Oxygen Depletion Sensor has been activated Open w indow s slightly or install ventilat...

Страница 25: ...TERMS OF THE PALOMA RHEEM WARRANTY AND EXCLUSIONS TO IT 1 The decision of whether to repair or replace a component or full replacement of the convection heater is at Paloma Rheem s sole discretion 2 W...

Страница 26: ...d the issue s are related to the installation or is due to the failure of electric or gas supplies 12 If you require a call out and we find that the fault is not covered by Paloma Rheem s warranty you...

Страница 27: ...purchase require proof of purchase and serial number from the rating label on the convection heater 2 Rheem will arrange for the convection heater to be tested and assessed on site 3 If Rheem determi...

Страница 28: ...he following 1 Please read these instructions carefully 2 Refer to trouble shooting page 23 and error code guide page 24 3 Contact Rheem Service These Paloma Rheem models have been certified by the Au...