background image

LIMITED WARRANTY

For the PALOMA Gas Water Heater Models listed on the front of this manual.

33

GENERAL

This Limited Warranty is only available to the original owner of this water heater at the original installation location. It is 
not transferable. Residential is defi ned as a single family residence dwelling occupied by the original owner.
Paloma Industries, Inc. (Paloma) warrants this Paloma water heater, and its component parts, to be free from defects in 
materials and workmanship, under normal use and service, for the Applicable Warranty Periods. At its option, Paloma will 
repair or replace the defective water heater, or defective component part(s), in accordance with the terms of this Limited 
Warranty, if it fails in normal use and service during the Applicable Warranty Periods. The replacement water heater must 
be manufactured by Paloma. The replacement component part(s) must be Paloma authorized component part(s). The 
replacement unit or component part(s) will be warranted only for the unexpired portion of the original unit’s Applicable 
Warranty Periods. Paloma strongly recommends that this water heater be installed by a contractor which is licensed, state 
qualifi ed, and trained on Paloma’s tankless products since improper installation may invalidate warranty coverage.

EFFECTIVE DATE

The Effective Date of warranty coverage (or the beginning of the Applicable Warranty Periods) is the date of purchase 
of this water heater, if properly documented. Otherwise, it is the date of manufacture of the water heater plus ninety (90) 
days.

APPLICABLE WARRANTY PERIODS

(Residential Models)
If the water heater is installed in a single-family dwelling and is used as normal residential usage with potable water, the 
Applicable Warranty Periods are twelve (12) years from the Effective Date for the heat exchanger, fi ve (5) years from the 
Effective Date for the component parts, and one (1) year for certain labor as described under the heading, LABOR, SHIP-
PING AND PROCESSING COST.
All Applicable Warranties will be limited to three (3) years from the Effective Date if the water heater is installed in a 
system in which the water is re-circulated, but not if it is an on-demand re-circulation system which utilizes existing hot 
and cold water lines, or a dedicated return line without the use of a temperature sensor, timer, or a continuously operating 
pump.
All Applicable Warranty Periods will be limited to one (1) year from the Effective Date if the water heater is installed 
anywhere other than a single-family dwelling.

(Commercial Models)
If the water heater is installed in a commercial application, the Applicable Warranty Periods are fi ve (5) years from the 
Effective Date for the heat exchanger, fi ve (5) years from the Effective Date for the component parts, and one (1) year for 
certain labor as described under the heading, LABOR, SHIPPING AND PROCESSING COST.
All Applicable Warranties will be limited to three (3) years from the Effective date if the water heater is installed in a 
system in which the water is re-circulated, but not if it is an on-demand re-circulation system which utilizes existing hot 
and cold water lines, or a dedicated return line without the use of a temperature sensor, timer, or a continuously operating 
pump.

WARRANTY EXCLUSIONS

This Limited Warranty will 

not 

cover:

a) Service trips to your location to teach you how to install, use, or maintain this water heater or to bring the water heater
    installation into compliance with local building codes and regulations.
b) Damages, malfunctions or failures resulting from failure to install the water heater in accordance with applicable build
    ing codes/ordinances or good plumbing and electrical trade practices or defective fi ttings.
c) Damages, malfunctions, or failures resulting from improper installation or failure to operate and maintain the water
    heater in accordance with the manufacturer’s instructions provided, including outside of recommended water quality
    levels.
d) Performance problems caused by improper sizing of the water heater or the gas supply line, the venting connection,
    combustion air openings, electric service voltage, wiring, or fusing.
e) Damages, malfunctions, or failures caused by improper conversion from natural gas to LP gas or LP gas to natural gas
    fuel source.
f) Damages, malfunctions, or failures caused by operating the water heater with any parts removed or with modifi ed, 
    altered, or unapproved parts installed.
g) Damages, malfunctions, or failures caused by abuse, accident, fi re, fl ood, freeze, lightning, acts of God, misuse, 
    alteration, and the like.
h) Heat Exchanger failures (leaks) caused by operating the water heater in a corrosive or contaminated atmosphere or
    damages, malfunctions or failures caused by lime, scale or mineral build-up.

Содержание PH-25R OFN

Страница 1: ...lation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includ...

Страница 2: ...r heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THIS MANUAL Your safet...

Страница 3: ...e not limited to adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near...

Страница 4: ...this adjustment Only factory authorized remote control s should be used Notice When this water heater is supplying general purpose hot water requirements for use by individuals a thermostatically cont...

Страница 5: ...e or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to...

Страница 6: ...ntial water heaters of a capacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures Have the installer show you the location of t...

Страница 7: ...re which may result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater...

Страница 8: ...ighbor s phone Follow the gas supplier s instructions l If you cannot reach your gas supplier call the fire department l Do not return to your home until authorized by the gas supplier or fire departm...

Страница 9: ...level 12 inches 30 cm above anticipated snow level B Clearance to window or door that may be opened 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 10...

Страница 10: ...ccidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticipated snow level 1 8 m If soffit vent is too close block off and install new vent...

Страница 11: ...of 0 66 gpm 2 5 lpm A water pressure of 40 psi 276 kPa is required to achieve maximum flow rate To maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min O...

Страница 12: ...flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve between the water heater and...

Страница 13: ...e relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be...

Страница 14: ...ion of CSA B149 1 Natural Gas and Propane installation code Manual Gas Supply Line Shutoff Manual Gas Appliance Shutoff Union Sediment Trap Cap Valve Supplied Leak Testing The water heater and its gas...

Страница 15: ...absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22 1 Part 1 F PRIORITY POWER ON OFF MAIN Control Base Plate Cont...

Страница 16: ...e base plate Ensure the projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control using the screw provided Proceed...

Страница 17: ...THERMISTOR D AIR AMBIANT WATER INLETTHERMISTOR THERMISTOR D ADMISSION D EAU HEAT EXCHANGERTHERMISTOR THERMISTOR D ECHANGEUR DE CHALEUR OUTLET HOTWATERTHERMISTOR THERMISTOR DE SORTIE D EAU CHAUDE THER...

Страница 18: ...alve manufacturer s instructions Water Inlet Water Outlet Drain Pressure Relief Valve Hot Water Service Valve Cold Water Service Valve Alternate Water Piping Arrangement with Optional Valve Kit Outdoo...

Страница 19: ...the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or def...

Страница 20: ...nd piping Water connections tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated and protected from freezing C Gas Suppl...

Страница 21: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Страница 22: ...as to the water heater If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perf...

Страница 23: ...nnot be increased above 112 F 44 C when a hot water faucet is in the open position Notice The factory setting allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of 85 F 29 C...

Страница 24: ...the hot water heater discharges periodically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT plug the relief valve...

Страница 25: ...NOT scrub the appliance with a brush Use only mild soapy water other cleaners may damage the surface of the water heater DO NOT remove any label including the rating plate while cleaning or servicing...

Страница 26: ...ter may be exposed to freezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of vent...

Страница 27: ...Valve Malfunctions if applicable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water de...

Страница 28: ...ower supply not grounded Low inlet gas pressure due to improper sizing Wrong gas type Open the Gas shutoff valve fully Contact gas utility company Fill up LP Gas container or replace with a new cylind...

Страница 29: ...as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring gas piping burners vent connectors or other safety devices Refer repairs to qualified serv...

Страница 30: ...seconds Number 120 on the display of the remote control will begin to blink While the number is blinking push the UP arrow temperature adjustment button and the Down arrow temperature adjustment butto...

Страница 31: ...ter heater may not function properly NOTICE If the water heater is installed less than 3 280 feet 1 000m no action is required How to adjust the DIP switch on the PCB for high altitude installation Ch...

Страница 32: ...Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following informatio...

Страница 33: ...line without the use of a temperature sensor timer or a continuously operating pump All Applicable Warranty Periods will be limited to one 1 year from the Effective Date if the water heater is instal...

Страница 34: ...ter heater or component part s Paloma will not reimburse any party for these or any other fees not specifically covered in this Limited Warranty document HOW TO OBTAIN WARRANTY CLAIM ASSISTANCE Any cl...

Страница 35: ...moved or the date of purchase of the part If it was purchased separately to establish the In warranty status of the defective component part If Paloma determines that the water heater or component par...

Страница 36: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN PII 0309...