background image

24

Care Instructions

CARING FOR YOUR WATER HEATER

Problem

Possible Cause

Solution

Water not hot enough.

 1. 

The temperature may be set too low.

 1. 

Increase the temperature setting at 

the remote control.

 2. 

The gas valve is not completely 

opened.

 2. 

Check and completely open the gas 

valve.

 3. 

Gas supply pressure is low.

 3. 

Contact your gas utility company or 

gas contractor to verify the gas meter 
and gas piping size.

 4. 

Bleed-over in one of the hot water 

fixtures.

 4. 

Contact a dealer or a qualified service 

technician.

Water too hot.

 1. 

Temperature is set too high.

 1. 

Decrease the temperature setting at    

the remote control.

 2. 

Water shut-off valve is not completely 

opened.

 2. 

Check and completely open the water 

shut-off valve.

 3. 

Small amount of water has been 

heated.

 3. 

Increase the hot water flow at the  

faucet to allow more water to flow  
through the water heater.

Fan continues to rotate after the hot water 
faucet is closed.

The post-purge cycle clears flue gases.

Normal operation.

1

2

3

1

2

Troubleshooting Chart (cont.)

Содержание 0ECOH160DV

Страница 1: ...using death personal injury or property damage For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance To do so may result in...

Страница 2: ...erts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER WARNING CAUTION or NOTICE 2 These words mean IMPOR...

Страница 3: ...and adhesives are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere in the vicinity of a water heater or any other appliance Be sure to read...

Страница 4: ...ast 30 minutes to melt the frozen water or the water heater may not work properly NOTICE The factory setting allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of 85 F 29 C a...

Страница 5: ...leak Some people may not physically be able to smell or recognize this odorant If you are unsure or unfamiliar with the smell of natural gas or LP ask the gas supplier Other conditions such as odorant...

Страница 6: ...this label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5...

Страница 7: ...ed only by qualified service personnel Make certain the power to the water heater is OFF before removing the unit cover panel Exposed electrical components and moving parts can cause personal injuries...

Страница 8: ...ut off Be sure your water heater is properly installed in accordance with local codes and the provided installation instructions Do not attempt to repair or replace any part of your water heater unles...

Страница 9: ...4 248 mm 21 4 59 mm 51 2 140 mm 61 8 156 mm 21 8 54 mm 37 8 98 mm 27 8 73 mm 41 8 105 mm 91 2 241 mm 11 2 38 mm Specifications Direct Vent Models 177 8 454 mm 185 8 473 mm 275 8 702 mm 93 4 248 mm 21...

Страница 10: ...u hr 11 000 11 000 Recover Rating gal hr 178 226 Shipping Weight lbs 81 81 Minimum Activation Flow Rate gpm 0 40 0 40 Extinction Flow Rate gpm 0 25 0 25 Hot Water Capacity gpm 35 F rise 8 5 9 5 Hot Wa...

Страница 11: ...ower Switch To Hot Water Faucet s Drain Valve Water Filter Cold Water Supply Shut Off Valve Note A flexible drain tube can be used To Suitable Drain To Suitable Drain Power Supply Cord Union Union Man...

Страница 12: ...Gas Supply Line Shut Off Valve Manual Gas Shut Off Valve Cap Sediment Trap Service Valve Relief Valve Relief Valve Note A flexible drain tube can be used To Suitable Drain To Suitable Drain Condensat...

Страница 13: ...death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Temperatu...

Страница 14: ...eater may not operate with a small water flow Increase the water flow and recheck If it still does not operate with the hot water faucet completely open increase the temperature setting on the remote...

Страница 15: ...ndling and discharge methods Do not operate without the condensate collector drain connected and routed to the proper drain This could cause the system to malfunction or fail On a regular basis inspec...

Страница 16: ...Turn on a hot water faucet While the water heater is operating inspect the main burner flames through the burner sight glass The flames should be blue when the main burner is firing NOTICE If the flam...

Страница 17: ...off and the electrical power supply disconnected Vacuum around the water heater to remove any dust dirt and or lint buildup Clean the water heater and the remote control with a damp soft cloth and mil...

Страница 18: ...out of the line Clean the water filter under running water To remove severe sediment and dirt use a soft brush CAUTION Do not overtighten the water filter Overtightening can deform and or damage the f...

Страница 19: ...After several gallons have drained release the lever handle to close the valve and stop draining NOTICE If the pressure relief valve on the hot water heater discharges periodically this may indicate...

Страница 20: ...disconnect the power supply at the circuit breaker box Open all hot water faucets Run the water until it is COLD then shut off the faucet Close the water shut off valve Using a suitable container to...

Страница 21: ...not work properly until this water is thawed To put the water heater back in service Disconnect drain hose Make sure the drain valve is closed Reinstall the water filter in the base of the cold water...

Страница 22: ...e water heater down to an ambient temperature of approximately 30 F 34 C These temperatures are all based on temperatures without wind The heater only protects the internal components of the water hea...

Страница 23: ...le Cause Solution Not enough or no hot water 1 Unit is not ON 1 Turn on the unit by pressing the POWER ON OFF button 2 Water shut off valve is not completely opened 2 Check shut off valve and open com...

Страница 24: ...g size 4 Bleed over in one of the hot water fixtures 4 Contact a dealer or a qualified service technician Water too hot 1 Temperature is set too high 1 Decrease the temperature setting at the remote c...

Страница 25: ...nectors or other safety devices Refer repairs to a qualified service technician When an error code is displayed Turn off all the hot water faucets Turn off the water heater by pressing the POWER ON OF...

Страница 26: ...nit can be used for a while but contact a dealer or qualified service technician 93 The neutralizer must be replaced The unit cannot be used until the neutral izer is replaced Contact a dealer or qual...

Страница 27: ...INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Installation...

Страница 28: ...th flammable vapors are used or stored Such liquids include gasoline LP gas butane or propane paint adhesives and their thinners solvents or removers Flammable vapors carry long distances from where t...

Страница 29: ...ncombustible construction are as follows 1 2 in 1 3 cm for sides 0 in 0 cm for rear with support bracket s 12 in 30 cm from the bottom top and front 12 min 300 mm 12 min 300 mm 1 2 min 13 mm 12 min 30...

Страница 30: ...ing a water heater in any of the following locations beauty shops dry cleaning establishments photo processing labs and storage areas for liquid and powdered bleaches or swimming pool chemicals These...

Страница 31: ...llation of Direct Vent Water Heater Venting Required To Hot Water Faucet s Drain Valve Wall Plate Water Filter Cold Water Supply Shut Off Valve Power Supply Cord Union Union Union Manual Gas Supply Li...

Страница 32: ...t s Drain Valve Cold Water Supply Shut Off Valve Hard Wire Union Manual Gas Supply Line Shut Off Valve Flue Terminal Cap Sediment Trap Manual Gas Shut Off Valve Water Filter Union Union Service Valve...

Страница 33: ...to wall If mounting to dry wall or concrete wall use drywall anchors or lag bolts Make sure the proper electrical outlet or supply 120 VAC 60 Hz is available and located near the unit Direct vent mod...

Страница 34: ...lowing recommended pipe material Use only 2 or 3 inch diameter pipe Refer to local codes for restrictions on the use of PVC CPVC or ABS pipe and fittings All exhaust venting materials for product inst...

Страница 35: ...water heater a thorough inspection of the existing venting and air intake system must be performed prior to any installation work Verify that the correct materials vent lengths and terminal locations...

Страница 36: ...e detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be perman...