11
ROBATA 72/54 CONCRETE FIRE CE Match-lit | Installation & Owner’s Manual
LIGHTING YOUR FIRE PIT
STOP!
Review the safety information on
pages 1, 2 and 10 of this manual.
150°
90°
30°
OFF
PILOT
HIGH
LOW
OPERATING INSTRUCTIONS
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
1. Turn the gas control knob to the OFF position (it will be necessary to depress the knob slightly
at the PILOT position). Allow five minutes for any gas in the vicinity to dissipate. (LP gas, which
is heavier than air, may require forced ventilation).
2. Push knob slightly and turn the gas control knob to the PILOT position.
3. Push down on the gas control knob and light the pilot immediately by applying a flame to the
lighting port. Hold the knob down for one full minute after lighting the pilot.
4. When the gas control knob is released, the pilot flame should continue to burn (if the pilot
goes out, repeat the above steps).
5. Rotate the gas control knob without pushing, from PILOT to HIGH position (90°
counterclockwise position) to supply full flow to main burner.
NOTE: Not turning the gas control knob to the full ON position will reduce the flow and could result
in poor ignition of main burner.
6. To extinguish main burner, rotate the gas control knob clockwise to the PILOT position.
7. To extinguish pilot, depress control knob slightly and turn to the OFF position (fully clockwise).