WARRANTY INFORMATION

RETAIN FOR WARRANTY

MODEL: (circle)   

Kodo 72-M 

  

   Natural 

Gas

   

 

 

 

Propane 

SERIAL NO:

DATE PURCHASED:

LIMITED WARRANTY

This product is warranted to the original owner, subject to proof of purchase: 

BASIC WARRANTY

Paloform warrants the components and materials in your appliance to be free from manufacturing and material 

defects for a period of one year from date of installation. After installation, if any of the components manufactured 

by Paloform in the appliance are found to be defective in materials or workmanship, Paloform will, at its option, 

replace or repair the defective components at no charge to the original owner. Paloform will also pay for reasonable 

labor cost incurred in replacing or repairing such components for a period of one year from date of installation. Any 

products presented for warranty repair must be accompanied by a dated proof of purchase.

This Limited Warranty will be void if the appliance is not installed by a qualified installer in accordance with 

installation instructions. The Limited Warranty will also be void if the appliance is not operated and maintained 

according to the operating instructions supplied with the appliance, and does not extend to (1) fireplace burner 

assembly damaged by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation 

thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the 

appliance, or (3) incidental or consequential damage. All service work must be performed by an authorized service 

representative.

This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability 

of fitness for purpose and of all other obligations or liabilities. Paloform does not assume for it any other obligations 

or liabilities in connection with sale or use of the appliance. In states that do not allow limitations on how long 

an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not 

apply to you. You may also have additional right not covered in the Limited Warranty. Paloform reserves the right 

to investigate any and all the claims against this Warranty and decide upon method of settlement. For information 

about this warranty contact:

Paloform

888.823.8883

[email protected]

`

Содержание KODO 72

Страница 1: ...ANGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Burner conforms to ANSI Z21 97 CSA 2 41 2017 Outdoor Decorative Gas Appliances CSA 2 17 2017 Gas fired Appliances for Use at High Altitudes We recommend that our fire pit...

Страница 2: ...ternational Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition 6...

Страница 3: ...nding on climate and weather conditions Rust will bleed until it stabilizes Do not place Cor Ten fireplaces on surfaces that will be permanently damaged or stained by rust bleed 1 UNPACK Account for all parts p 13 2 FRAGILE Handle with care 3 ANCHOR Anchor surround to slab or decking surface see pp 14 17 4 AIR VENTS Do not block ventilation gaps p 4 5 GAS PROPANE Supply line is routed through the ...

Страница 4: ... 52 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 26 43 Burner Ports 35 35 Port Size 1 8 1 8 DIMENSIONS SPECIFICATIONS FACE SIDE BOTTOM VENTILATION GAP DO NOT OBSTRUCT ACCESS PANEL OPTIONAL UNDERSIDE OPEN TO GROUND 18 457 mm 34 864 mm 72 1829 mm 18 457 mm 43 5 8 1108 mm 14 1 8 359 mm 48 1219 mm 24 610 mm 72 1829 mm 9 229 mm 44 1118 mm 12 1 4 311 mm...

Страница 5: ...5 KODO 72 OUTDOOR FIREPLACE Match lit Installation Owner s Manual MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 12 96 Zero Clearance to Side Zero Clearance Below ...

Страница 6: ...topping media lava rock or tempered glass pebble on top of burner media See page 7 Decorative media should be brought level with the top of the pilot cover An uneven or excessively thick layer of topping can result in an uneven flame Do not obstruct PILOT IGNITION PORT 9 Correct flame appearance WARNING Failure to position parts in accordance with these diagrams and instructions and or failure to ...

Страница 7: ...TIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG LAVA ROCK LP FILL BURNER MEDIA TRAY CAUTION Do not use any media over the burner that have not been supplied by Paloform Landscape stone or other natural or manufactured materials may explode when heated ...

Страница 8: ...an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Excess Of 1 2 psi 3 5 kPa This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in ...

Страница 9: ... has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or maintenance can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier ...

Страница 10: ...wn on the gas control key and light the pilot immediately by applying a flame to the lighting port Hold the key down for one full minute after lighting the pilot 4 When the gas control key is released the pilot flame should continue to burn if the pilot goes out repeat the above steps 5 Rotate the gas control key from PILOT to ON position full counterclockwise position to supply full flow to main ...

Страница 11: ... intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover to inspect pilot Remove topping from top of burner ring and Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner If any damage to the burner is eviden...

Страница 12: ...e 2 Check reset gas regulator pressure Gas odor even when manual valve is in the OFF position 1 Gas leak See Warning statement below 2 Main gas valve defective 1 Locate and correct all leaks see Checking Gas Connections pg 8 2 Replace gas valve Unit produces unwanted odors 1 Gas leak See Warning statement below 1 Locate and correct all leaks see Checking Gas Connections pg 8 Pilot cannot be lit 1 ...

Страница 13: ...2 LIN 36 Burner Tube LIN 36 ASSY same 2a Air Shutter 3 Orifice FIT ORI 26 FIT ORI 43 4 Media Tray LIN 36 ASSY A same 5 Burner Tray LIN 36 ASSY B same 6 Pipe Adpater 7 Pilot Assembly PIL M 388 PIL M 388LP 8 Regulator M REG RV20 NG M REG RV20 LP 9 3 8 Close Nipple 10 Valve Bracket set of 2 BEN32 BRA WR109 same 11 3 8 135 Street Elbow 12 Main Gas Valve M VAL WR 764 109 same 13 Control Key M KEY WR109...

Страница 14: ...UTDOOR FIREPLACE Match lit Installation Owner s Manual ANCHORING CONCRETE FOOTING ATTENTION Drawings are guidelines only Customer is responsible for ensuring that installation complies with local codes regulations ...

Страница 15: ...72 OUTDOOR FIREPLACE Match lit Installation Owner s Manual ANCHORING WOOD DECK ATTENTION Drawings are guidelines only Customer is responsible for ensuring that installation complies with local codes regulations ...

Страница 16: ...UTDOOR FIREPLACE Match lit Installation Owner s Manual ANCHORING WOOD DECK cont d ATTENTION Drawings are guidelines only Customer is responsible for ensuring that installation complies with local codes regulations ...

Страница 17: ...UTDOOR FIREPLACE Match lit Installation Owner s Manual ANCHORING WOOD DECK cont d ATTENTION Drawings are guidelines only Customer is responsible for ensuring that installation complies with local codes regulations ...

Страница 18: ... Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fireplace burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defective p...

Отзывы: