Environmental Specifications

Environmental Specifications

Table 11 lists environmental specifications for the PA-4000 Series.

Table 11.   Environmental Specifications 

Specification

Description

Operating temperature range

0° to 50° C

Storage temperature range

-20° to 70° C

System air flow

Front to back

Содержание PA-4000 Series

Страница 1: ...PA 4000 Series Hardware Reference Guide...

Страница 2: ...d for instructions on configuring the features on the firewall refer to https www paloaltonetworks com documentation For access to the knowledge base complete documentation set discussion forums and v...

Страница 3: ...nt Rack Installation 10 Connecting Cables to the Device 11 Connecting Power 12 Chapter 3 Maintaining the Hardware 13 Cautions and Warnings 13 Replacing a Power Supply 13 Interpreting the Device LEDs 1...

Страница 4: ...4 Table of Contents Palo Alto Networks...

Страница 5: ...to Networks COMPANY CONFIDENTIAL Chapter 1 Overview This chapter describes the features of the front and back panel of the PA 4000 Series firewall For more information refer to the following topics Fr...

Страница 6: ...to access the device management interfaces through an Ethernet interface Management console port One DB 9 port for connecting a serial console High availability HA ports Two RJ 45 ports for high avai...

Страница 7: ...s One RJ 45 port to access the device management interfaces through an Ethernet interface Management console port One DB 9 port for connecting a serial console High availability HA ports Two RJ 45 por...

Страница 8: ...The PA 4000 Series does not have a power button The device is powered by plugging power cords into the power supplies Refer to Replacing a Power Supply on page 13 for instructions on replacing the po...

Страница 9: ...ing shipping verify the following upon receipt of each product The tracking number provided to you electronically when ordering the product matches the tracking number that is physically labeled on th...

Страница 10: ...ambient room temperature Verify that the ambient temperature of the rack assembly meets the maximum rated ambient temperature requirements listed in Environmental Specifications on page 19 Reduced air...

Страница 11: ...les on the side of the device with holes in the rack rail Make sure that rack rail holes are selected so that the PA 4000 Series is level 4 Insert mounting screws into the aligned holes Tighten with a...

Страница 12: ...ctions for the PA 4000 Series Figure 7 Power Connection for the PA 4000 Series To power up the PA 4000 Series attach a power cable to each of the power supplies and plug each into a grounded wall outl...

Страница 13: ...trained service person s Replacing a Power Supply The PA 4000 Series firewall has two hot swappable power supplies Both power supplies should be connected during normal operations If the system detec...

Страница 14: ...t Interpreting the Device LEDs Figure 9 shows the LED dashboard on the front panel and Table 4 describes the LED functions and states Figure 9 Front Panel LEDs Note The audible alert continues to be g...

Страница 15: ...rature is normal Yellow The temperature is outside the normal tolerance ALARM Red There is a hardware failure which may include power supply detected but not working fan failure HA failover or tempera...

Страница 16: ...ribes the LEDs for the PA 4000 Series Management port Refer to Figure 1 and Figure 2 Table 7 PA 4000 Series Management Port LEDs LED Description Left Shows green when a 100 Mbps link is connected or a...

Страница 17: ...Specifications in the next section Interface Specifications on page 18 Electrical Specifications on page 18 Environmental Specifications on page 19 Physical Specifications Table 8 lists physical speci...

Страница 18: ...rk traffic PA 4060 Four SFP ports for network traffic XFP ports PA 4060 Four 10 Gigabit Small Form Factor Pluggable XFP ports for network traffic Management ports One RJ 45 port to access the device C...

Страница 19: ...Environmental Specifications Table 11 lists environmental specifications for the PA 4000 Series Table 11 Environmental Specifications Specification Description Operating temperature range 0 to 50 C S...

Страница 20: ...Environmental Specifications 20 Specifications Palo Alto Networks...

Страница 21: ...he Voluntary Control Council for Interference by Information Technology Equipment VCCI which governs radio frequency emissions in Japan The following information is in accordance to VCCI Class A requi...

Страница 22: ...22 Compliance Statement Palo Alto Networks...

Отзывы: