Palmgren 80171 Скачать руководство пользователя страница 4

4

INSTALLATION (CONTINUED)

GROUNDING INSTRUCTIONS
WARNING:

Improper connection of equipment grounding con-

ductor can result in the risk of electrical shock. Equipment should
be grounded while in use to protect operator from electrical shock.

Check with a qualified electrician if grounding instructions are not
understood or if in doubt as to whether the tool is properly
grounded.

This tool is equipped with an approved 3-conductor cord rated up
to 240V and a 3-prong grounding type plug rated at 115V (See
Figure 1) for your protection against shock hazards.

Grounding plug should be plugged directly into a properly
installed and grounded 3-prong grounding-type receptacle, as
shown (Figure 1).

Do not remove or alter grounding prong in any manner. In the
event of a malfunction or breakdown, grounding provides a path
of least resistance for electrical shock.

WARNING:

Do not permit fingers to touch the terminals of plug

when installing or removing from outlet.
Plug must be plugged into matching outlet that is properly
installed and grounded in accordance with all local codes and
ordinances. Do not modify plug provided. If it will not fit in outlet,
have proper outlet installed by a qualified electrician.
Inspect tool cords periodically, and if damaged, have repaired by
an authorized service facility.
Green (or green and yellow) conductor in cord is the grounding
wire. If repair or replacement of the electric cord or plug is neces-
sary, do not connect the green (or green and yellow) wire to a live
terminal.
Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle installed in
accordance with National Electric Code and local codes and ordi-
nances.
WARNING: This work should be performed by a qualified electrician.
A temporary 3-prong to 2-prong grounding adapter (See Figure 2)
is available for connecting plugs to a two pole outlet if it is 
properly grounded.

Do not use a 3-prong to 2-prong grounding adapter unless permit-
ted by local and national codes and ordinances.

(A 3-prong to 2-prong grounding adapter is not permitted in
Canada.) Where permitted, the rigid green tab or terminal on the
side of the adapter must be securely connected to a permanent
electrical ground such as a properly grounded water pipe, a prop-
erly grounded outlet box or a properly grounded wire system.

Many cover plate screws, water pipes and outlet boxes are not
properly grounded. To ensure proper ground, grounding means
must be tested by a qualified electrician.

EXTENSION CORDS

The use of any extension cord will cause some drop in voltage
and loss of power.

Wires of the extension cord must be of sufficient size to carry
the current and maintain adequate voltage.

Use the table to determine the minimum wire size (A.W.G.)
extension cord.

Use only 3-wire extension cords having 3-prong grounding
type plugs and 3-pole receptacles which accept the tool plug.

If the extension cord is worn, cut, or damaged in any way,
replace it immediately.

EXTENSION CORD LENGTH

Wire Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.W.G.
Up to 25 ft.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
25-50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
NOTE: Using extension cords over 50 ft. long is not recommended.

POWER SOURCE

Drill press requires a 115/230 volt, 60 Hz power source.

To use the drill press with a 230V power supply, have a qualified
electrician attach a 230 volt, 20/30A three-prong plug onto drill
press line cord.

ELECTRICAL CONNECTIONS

Refer to Figure 3.

WARNING:

All electrical connections must be performed by a

qualified electrician. Make sure unit is off and disconnected from
power source while motor is mounted, connected, reconnected or
anytime wiring is inspected.

The motor should be wired for 115 volts an clockwise rotation
as viewed from shaft end of motor.

A label on the motor describes the possible wiring configura-
tions. There are many different possible  combinations, so only
the diagram provided with the motor should be used.

Be sure to install motor cord so that the cover plate for the motor
wiring holds the cord in the groove of the motor end shield. The
motor cord must be secured to protect the wiring connections
from possible strain.

The power supply to motor is controlled by a locking rocker
switch. Power lines are connected to the quick connect termi-
nals of the switch.

The green ground line must remain securely fastened to the
motor ground terminal to provide proper grounding.

To operate drill press at 230 volts, rewire motor as shown in
Figure 3 and replace line cord plug with a 230 volt, 15A, 3-prong
plug. If motor label has a different wiring configuration, use the
motor label diagram to rewire motor.

Palmgren Operating Manual & Parts List

80171 & 80172

Figure 2 – 2-Prong Receptacle with adapter

Grounding Lug

Adapter

3-Prong Plug

2-Prong Receptacle

Make sure this is
Connected to a known
Grounded Receptacle

Figure 1 – 3-Prong Receptacle

Properly Grounded Outlet

Grounding Prong

3-Prong Plug

Figure 3 – Wiring Schematic for Motor

To Change Rotation, Exchange Leads 5 and 6
U, V-Power Supply

115 Volts

1

3

5

2

4

6

230 Volts

1

U

V

U

V

2

3

5

4

6

Содержание 80171

Страница 1: ...rating manual parts list 80171 80172 17 HEAVY DUTY BENCH AND FLOOR MODEL DRILL PRESSES Read carefully and follow all safety rules and operating instructions before first use of this product 20154 09 0...

Страница 2: ...latile solvents Avoid getting clean ing solution on paint as it may tend to deteriorate these finishes Use soap and water on painted components SPECIFICATIONS Chuck size 3 16mm JT3 Spindle taper MT2 S...

Страница 3: ...7 to shaft own worm gear Ref No 11 rotate worm gear to remove slack and shoulder crank handle with socket head bolt Ref No 6 Slide table Ref No 16 into hole in table arm Secure table with table lockin...

Страница 4: ...es are not properly grounded To ensure proper ground grounding means must be tested by a qualified electrician EXTENSION CORDS The use of any extension cord will cause some drop in voltage and loss of...

Страница 5: ...r face This permits drilling of larger objects Clamp table securely after adjustments have been made DEPTH STOP ADJUSTMENT Refer to Figure 6 To control drilling depth use scale Ref No 25 to adjust to...

Страница 6: ...ubricate the splines grooves in the spindle and the rack teeth on the quill as follows Lower quill assembly Figure 6 Ref No 19 all the way down Apply lubricant around the inside of the hole in the spi...

Страница 7: ...g bit or excessive feed 2 Improper belt tension 3 Workpiece not supported or clamped properly CORRECTIVE ACTION 1 Check wiring fuse or circuit breaker 2 Replace switch 3 Replace motor Replace bearings...

Страница 8: ...8 Figure 5 Replacement Parts Illustration for Base Palmgren Operating Manual Parts List 80171 80172 11 6 19 10 8 12 18 6 5 4 15 16 17 7 23 21 20 22 25 24 13 14 26 2 3 9 1...

Страница 9: ...1 12 3AMI 14 Retaining Ring 05989 00 05989 00 1 13 Rack Retaining Ring 17237 00 17237 00 1 14 Bushing 17238 00 17238 00 1 15 Table Bracket Locking Handle 17239 00 17239 00 1 16 Table 17240 09 17240 09...

Страница 10: ...arts Illustration for Head 35 62 66 67 68 32 30 65 23 53 74 14 73 13 13 29 59 36 20 30 41 4 51 52 61 71 72 39 7 50 6 9 8 28 43 13 5 49 3 3 3 2 1 22 33 34 75 60 26 11 37 46 44 54 49 38 42 69 12 27 25 2...

Страница 11: ...ring 17266 00 1 40 12 1 75mm Hex Jam Nut 2 Ref No Description Part No Qty 41 3BMI 52 Retaining Ring 02445 00 2 42 Spacer 17267 00 1 43 Spindle Sleeve 17268 00 1 44 Upper Spindle Assembly 17269 00 1 Re...

Страница 12: ...r a non warranty repair please contact your preferred Palmgren distributor To obtain the names of Palmgren distributors or to arrange warranty return please call Palmgren Steel Products directly at 80...

Отзывы: