background image

WARNING: 

Use of equipment in unintended applications may 

Personal Fall Arrest: 

C0850 may be used to support a 

result in serious injury  or death. Maximum 1 attachment per 

MAXIMUM 1 Personal Fall Arrest Systems (PFAS) for use in Fall 

connection point. 

Arrest applications. Structure must withstand loads applied in the 
directions permitted by the system of at least 15kN.

Personal Fall Arrest: C0850 may be used in Personal Fall Arrest 
applications to support a MAXIMUM 1 Personal Fall Arrest System 

Restraint

: C0850 may be used in Restraint applications. 

(PFAS). Structure must withstand loads applied in the directions 

Restraint systems prevent workers from reaching the leading edge 

permitted by the system of at least 5,000 lbs. 

of a fall hazard. Always account for fully deployed length of 
lanyard/SRL.  Structure  must  withstand  loads  applied  in  the 

Restraint: VLA may be used in Restraint applications. Restraint 

directions permitted by the system of at least 15kN. No free fall is 

systems prevent workers from reaching the leading edge of a fall 

permitted.

hazard. Always account for fully deployed length of lanyard/ VLA. 
Structure must withstand loads applied in the directions permitted. 

For all applications: worker weight capacity range (including 

Restraint system may only be used on surfaces with slopes up to 

all clothing, tools, and equipment) is 310 lbs.

4/12 (vertical horizontal). Applicable D-rings: 

NEVER for simultaneous use in Fall Arrest and Restraint

For all applications: worker weight capacity range (including all 

Swing Falls:

 Prior to installation or use, make considerations for 

clothing, tools, and equipment) is 130-310 lbs.

eliminating or minimizing all swing fall hazards. Swing falls occur 

VLA: Inspection 

when the anchor is not directly above the location where a fall 
occurs. Always work as close to in line with the anchor point as 

KEEP INSTRUCTIONS AVAILABLE FOR REFERENCE. 

possible. Swing falls signicantly increase the likelihood of serious 
injury or death in the event of a fall.

Record date of rst use

Compatibility:

  When  making  connections  with  C0850, 

Prior to each use, inspect the VLA for deciencies, including, but not 

eliminate all possibility of roll-out. Roll-out occurs when interference 

limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp 

between a hook and the attachment point causes the hook gate to 

edges, cracking, rust, paint buildup, excessive heating, alteration, 

unintentionally open and release. All connections must be selected 

broken stitching, fraying, bird caging, and missing or illegible labels. 

and deemed compatible with C0850 by a Competent Person. 

IMMEDIATELY remove VLA from service if defects or damage are 
found, or if exposed to forces of fall arrest.

Ensure that applicable work area is free of all damages, including, 
but not limited to debris, rot, rust, decay, cracking, and hazardous 
materials.  Ensure  that  selected  work  area  will  support  the 
application–specic minimum loads set forth in this instruction 
manual. Work area must be stable.   

At least every month, a competent person other than the user must 
inspect VLAs. Competent Person inspection MUST be recorded in 
instruction manual and on equipment inspection grid label. The 
Competent Person must sign their initials in the box corresponding 
to the month and year the inspection took place. 

During inspection, consider all application  

INSPECTION

Ø

KEEP  INSTRUCTIONS  AVAILABLE  FOR  REFERENCE. 
Record Date of First Use

Ø

Prior  to  EACH  use,  inspect  C0850

for  deciencies, 

including, but not limited to, corrosion, deformation, pits, burrs, 
rough surfaces, sharp edges, cracking, rust, paint buildup, 
excessive heating, alteration, broken stitching, fraying, bird-
caging, and missing or illegible labels. IMMEDIATELY remove 
C0850 from service if defects or damage are found, or if 
exposed to forces of fall arrest.

Ø

Ensure that applicable work area is free of all damage, 
including, but not limited to, debris, rot, rust, decay, cracking, 
and hazardous materials. Ensure that selected work area will 
support the application-specic minimum loads set forth in this 
instruction manual. Work area MUST be stable.

Ø

At least every 6 months, a Competent Person other than the 
user  must  inspect  C0850.

Competent  Person 

inspections  MUST  be  recorded  in  inspection  log  in 
instruction manual and on equipment inspection grid 
label. The Competent Person must sign their initials in the 
box corresponding to the month and year the inspection 
took place.

Ø

During inspection, consider all applications and hazards
C0850 have been subjected to.

PRODUCT SPECIFIC APPLICATIONS

WARNING: 

Use of equipment in unintended applications may 

result in serious injury or death. Maximum 1 attachment per 
connection point

Page 3 of 4

Markings 

The Fall Arrester is marked with :

(i)  Identication of the 

manufacturer

(ii)  Type or product code & Ref. No
(iii)  Batch No / Year of Manufacture
(iv) Maximum Rated Load: 500kg
(v) Read the manufacturer's 

instruction before use.

(vi) Minimum Breaking Strength

C0850

C0850