background image

4

Diagnostics and Remedies

I

f the dryer will not run

The dryer cycles by itself
or runs constantly

The  dryer  runs  but  air
stream is low pressure
and/or low velocity

Ensure that there is no obstruction on or in front of the IR sensor. Clean
any dirt or debris off the sensor lens. If problem persists, replace sensor.

First ensure that the breaker supplying the dryer is operational. If it is,
disconnect  the  power  and  remove  the  dryer  cover.  Taking  suitable
precautions to avoid shock hazard, reconnect the power and check for
Voltage at the terminal block. Verify that connections are made correctly.

Ensure that the supply Voltage is correct.  Dryer will run weakly if the
input Voltage is too low.  Verify Voltage requirement on unit rating label
and correct supply as required.

The dryer makes a loud
noise and does not run
for a complete cycle

Ensure that the supply Voltage is correct. Dryer will make a loud humming
noise if the input Voltage is too high. Verify Voltage requirement on unit
rating label and correct supply as required. If CBM has been damaged,
replace CBM, IR sensor module.

Symptom                                                                 

Corrective Actions for Initial Installation Failures

Symptom                                                                 

Corrective Actions for In-Service Failures

I

f the dryer will not run

The IR sensor only “sees”
close range objects

The dryer only blows cold
air during a full cycle

Ensure that there is no obstruction on or in front of the IR sensor. Clean
any dirt or debris off the sensor lens. If problem persists, disconnect the
power and remove the dryer cover and replace CBM, IR sensor module.

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,
disconnect  the  power  and  remove  the  dryer  cover.  Replace  the  CBM
and  IR  sensor  module.  Taking  suitable  precautions  to  avoid  shock 
hazard, reconnect the power and check for Voltage at the terminal block.

Disconnect the power. Remove the dryer cover and check/ ensure heater 
SW is ON. Disassemble the blower-motor/fan housing. Test the thermostat 
for open circuit. Check the heater element for signs of burning or breakage. 
Damaged element must

 

be replaced.

The  heater  gets  hot  but
no air stream is produced

Disconnect  the  power.  Remove  the  dryer  cover.  Check  VR  for  speed 
setting Disassemble the

 

blower- motor/ fan housing. Replace the fan motor.

Reassemble.

The  air  stream  is  low
pressure and velocity

Check the output nozzle for obstructions. If none are present, disconnect
the  power.  Remove  the  dryer  cover.  Remove  any  dust/lint  buildup  from 
intake  vent  slots.  Check  VR  for  speed  setting.  Disassemble  the  blower-
motor/fan housing. Check the motor brushes for worn condition (

 1-3/16” 

[30 mm] graphite remains) and replace them, if necessary.

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted 

ADA

-compliant hand dr yer 

Important Information

This Product falls within the scope of the Waste Electrical &
Electronic Equipment Directive 2002/96 EC.       (WEEE)

NOTE:

This Product should not be disposed
of with household waste
Please recycle where facilities exist.
Check with your local authority for
recycling advice.

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

All manuals and user guides at all-guides.com

Содержание BLUSTORM BOLT

Страница 1: ...Fixture Company P O Box 10887 Green Bay WI 54307 1 800 558 8678 www palmerfixture com uto A distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com All manuals and user guides at all guide...

Страница 2: ...e Adjustable by Owner 325 450 W Auto Resetting Thermostat turns heater element off at 185 F 85 C Resets at 167 F 75 C Thermal cut off at 288 F 142 C Less than 15 seconds Infrared Automatic self adjust...

Страница 3: ...to terminal block where indicated and connect ground wire to base plate with ground screw Connections A Connect the live wire colored Brown Red or Black to the terminal block marked L B Connect the n...

Страница 4: ...ryer automatically starts operation Rub hands lightly and rapidly under the nozzle Dryer stops when hands are removed from sensor zone or if maximum time is reached Operating Instructions and Parts Ma...

Страница 5: ...ect the power and remove the dryer cover and replace CBM IR sensor module First ensure that the breaker supplying the dryer is operational If it is disconnect the power and remove the dryer cover Repl...

Страница 6: ...mounted ADA compliant hand dryer 5 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 Tools Req d Provided in kit L Wrench Item 23 distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect...

Страница 7: ...Sensor module Terminal block Rubber grommet Base Mylar shield with LNG marked Cable clamp Grounding screw with cup washer Cable protector Base plate Cover BluStorm Bolt Stainless steel Satin Security...

Отзывы: