Pall USD3295 Скачать руководство пользователя страница 15

www.pall.com/bio

tech

 

14

 

6.2 

Specification overview 

Basic Controlbox 

CE 

Advanced 

Controlbox CE

 

Basic Controlbox 

UL

 

Advanced 

Controlbox UL

 

Electical supply

 

230 Vac PN 

CBG401B 

CBG401A 

N/A 

N/A 

120 Vac PN 

N/A 

N/A 

CBG402B 

CBG402A 

Power socket 

Mennekes 

Mennekes 

Hubbell 

Hubbell 

Power cord 
with plug 

Bulgin 3pole panel mount 

connector and replaceable 

power cord  

Bulgin 3pole panel mount 

connector and replaceable 

power cord 

Nema 5-15 

Nema 5-15 

IP rating 

IP54 

IP54 

IP54 

IP54 

External Connections (Ethernet cable) 

to MVP via 

S7/S7 

S7/S7 

S7/S7 

S7/S7 

to 3 

rd

 party 

(DCS/PCS) via 

OPC-UA 

OPC-UA 

OPC-UA 

OPC-UA 

Measuring

 

Temperature 
via 

PT100 sensor/ 

display 

PT100 sensor/ 

display 

PT100 sensor/ 

display 

PT100 sensor/ 

display 

Weighing via 

Plug and play Binder 

connection (male 3 pole) 

Plug and play Binder 

connection (male 3 pole) 

Plug and play Binder 

connection (male 3 pole) 

Plug and play Binder 

connection ( male 3 pole) 

LevMixer Mixer 
speed via 

Turck cable (yellow) 

Turck cable (yellow) 

Turck cable (yellow) 

Turck cable (yellow) 

Lev

 

Mixer/Magnetic 
Mixer status of  
motor 
start/stop/ 
remote or 
local/alarms 

Turck cable (grey) 

Turck cable (grey) 

Turck cable (grey) 

Turck cable (grey) 

Optional 

pH via 

N/A 

sensor /display 

N/A 

sensor /display 

Conductivity via 

N/A 

sensor /display 

N/A 

sensor /display 

Hardware Specifications

 

Weight (kg)

 

Approx. 50 kg 

Approx. 50kg 

Approx. 50 kg 

Approx. 50 kg 

Dimensions in mm ( L x H x W) 

Exclusive 

  

500 x 500 x 300 

500 x 500 x 300 

500 x 500 x 300 

500 x 500 x 300 

trolley 
Inclusive trolley 

558 x 541 x 749 

558 x 541 x 749 

558 x 541 x 749 

558 x 541 x 749 

Materials of Construction 

Trolleys Frame 

304 stainless steel 

304 stainless steel 

304 stainless steel 

304 stainless steel 

Wheels 

Polyamide 6 

Polyamide 6 

Polyamide 6 

Polyamide 6 

Содержание USD3295

Страница 1: ...Instructions For Use Basic Advanced Controlbox USD3295 ...

Страница 2: ...vanced Controlbox 4 5 System Operation 6 5 1 Basic Advanced Controlbox connections 6 5 2 Installing the System 10 6 Specifications 13 6 1 Schematic System Overview 13 6 2 Specification overview 14 7 General Maintenance 15 8 WEEE Declaration 15 9 Warranty 15 10 Cleaning Recommendations 16 11 Manufacturer Details 16 12 Appendix 1 Wiring Diagram 17 13 Appendix 2 Cable Drawings 18 ...

Страница 3: ...t the materials of construction Please refer to Pall for exact limits for contact fluids and conditions This Basic Advanced Controlbox must only be used by persons who have been trained and authorized to do so 3 Receipt of Equipment 3 1 Basic Advanced Controlbox Hardware Takecare when removing the supplied Basic Advanced Controlbox hardware from the shipping container Use appropriate equipment whe...

Страница 4: ...truments that could damage the Basic Advanced Controlbox Do not open the packaging by forcing any of the system components through the sealed end becausethis cangenerateparticulatecontaminants Ensure that the system selected is suitable for the application ...

Страница 5: ...abinet In the front you can switch on off the main switch On the right side of the cabinet a plug socket is located Figure 4 1 Advanced Controlbox in CE left the cables coming from the cabinet right On the top side you can read the values from the display In case of the basic controlbox the temperature display is the only display In the advanced one you can also read out pH and conductivity on a s...

Страница 6: ...ox right Under the plug socket the cables for sensors connection cables to LevMixer Magnetic drive unit and weighing is located As well you can find 2 Ethernet cable connections Figure 4 4 Right side of the cabinet plug socket for power and 2 Ethernet cable connections ...

Страница 7: ...supply for drive unit marked with a Mixer tag MAIN SWITCH The system is equipped with one main switch installed on the Basic Advanced Controlbox When the main switch is off power supply to the system is switched off Figure 5 2 Main switches left UL right CE Fatal electric shock Some spots can be live even when the main switch is switched off refer to the wiring diagram Only trained personnel may w...

Страница 8: ...g cable to connect with counterpart on the tank with indicator WEIGHING MEASUREMENT Plug and Play strategy Weighing measurement via an easy plug and play cable connection between weighing indicator small cable with counterpart on the tank and the Basic Advanced Controlbox Plug the connector to the counterpart of the indicator MEASUREMENTS VIA SENSOR Temperature measurement via a cable from Basic A...

Страница 9: ...Advanced Controlbox EXTERNAL CONNECTION The system is equipped with two Ethernet ports which can be used for o Service connection to OPC Interface o Connecting the system to an external PLC connection Figure 5 5 Ethernet ports OPC Interface and External PLC Connection 24V DC POWER Used for supplying power to the PLC control and sensors It is a hardwired one for the UL versions For the CE version i...

Страница 10: ...emote or local status and alarm status is read by a grey cable connected via plug and play to the LevMixer or Magnetic Mixer Figure 5 6 LevMixer Magnetic mixer drive unit without connections with the Controlbox MVP SU TFF Figure 5 7 Cable connections at the bottom of a LevMixer Magnetic mixer drive unit Agitator speed cable Discrete I O Status cable Analog I O Connection to MVP SU TFF Allegro I O ...

Страница 11: ...ixer drive Magnetic drive unit Connect the MVP SU TFF cable to the drive unit 3 Connect the power cable 1 from the drive unit to the Controlbox power socket Connect the Ethernet cable Plug the Ethernet cable in the Ethernet socket for o Service connection to OPC Interface o Connecting the system to an external PLC connection e g MVP Data transfer 1 1 2 2 3 1 1 ...

Страница 12: ...e sensors in the bag of the tank Connect the weighing cable of the Basic Advanced Controlbox 1 with the indicator cable of the weighing 2 equipped with a safety cap Plug in the plug in the power socket of the Basic Advanced Controlbox Turn on power 1 1 2 ...

Страница 13: ...ning the system On the Basic Advanced Controlbox screen of the display you can see the values After your measurement is over you reinstall your probes from the Mixer bag disconnect the weighing cable and switch the main power of ...

Страница 14: ...1 Schematic System Overview On the following schematic the dependences are shown It is divided in the end customer part the Controlbox section and the Pall mixer tank section as well as the Pall drive unit and MVP section ...

Страница 15: ...male 3 pole Plug and play Binder connection male 3 pole Plug and play Binder connection male 3 pole Plug and play Binder connection male 3 pole LevMixer Mixer speed via Turck cable yellow Turck cable yellow Turck cable yellow Turck cable yellow Lev Mixer Magnetic Mixer status of motor start stop remote or local alarms Turck cable grey Turck cable grey Turck cable grey Turck cable grey Optional pH ...

Страница 16: ...ower cord Connection to power supply via power cables 6 AU LT SVSP367 Replaceable power cord Connection to power supply via power cables 8 WEEE Declaration The presence of this label on a product means that the product contains electrical or electronic materials and therefore should not be disposed of as unsorted waste but instead treated separately The presence of these materials may if not dispo...

Страница 17: ...less steel components and UCI can be cleaned using a soft cloth and a neutral detergent or alcohol solution Do not use abrasive cleaning agents 11 Manufacturer Details The Basic Advanced Controlbox is manufactured by Pall GmbH Philipp Reis Str 6 63303 Dreieich Germany ...

Страница 18: ...12 Appendix 1 Wiring diagram ...

Страница 19: ...www pall com biotech 18 13 Appendix 2 cable drawings ...

Страница 20: ...u visit www pall com contact The information provided in this literature was reviewed for accuracy at the time of publication Product data may be subject to change without notice For current information consult your local Pall distributor or contact Pall directly 2018 Pall Corporation Pall and Allegro are trademarks of Pall Corporation indicates a trademark registered in the USA TM indicates a com...

Отзывы: