UH319

UH319 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

3

Note: Painting of the filter housing is optional. The coating on
the filter housing is a suitable painting base. Cover the
differential pressure warning device and nameplate if painting
of the housing takes place.

4.8

Bleed the filter

4.8.1 UH319C series (cover service): Bleed the filter by

opening the vent plug (7) at the top of filter one and one
half turns. Jog system and fill filter until all air bleeds
through the plug, then torque tighten the vent plug to 
12 ft/lb or 16Nm.

4.8.2  UH319H series (head service): Bleed the filter by opening

the blanking plug (6b) one and one-half turns. Jog system
and fill filter until all air bleeds through the plug, then
torque tighten the blanking plug to 40 ft/lb or 54 Nm.

Pressurize system fully and check for leaks; if leaks occur 
refer to section 5.

5

Routine maintenance

5.1

Pall

filters do not normally require special attention

except for periodic monitoring of the differential pressure
warning device. Schedule replacement of filter element
every six months or sooner, and have ample supply of
spare elements available. 

5.2

If external leakage is noted, replace O-ring at leak. If
leakage persists, check sealing surfaces for scratches or
cracks; replace any defective parts. 

5.3

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. If 'cold start' conditions exist, see
Section 6.2 and 6.3.

5.4

A dirty system can quickly plug a new filter element,
especially with 

Pall

high efficiency filter media. It may

require one or two initial element changes to stabilize
element life. If element life is short or differential
pressure is excessive, filter may be undersized; refer to
the sizing and selection section of the product literature
or contact your local Pall representative.

5.5

Make sure element change labels are clean and
undamaged. Replace illegible labels with the appropriate
new labels.

6

Differential pressure devices

Reference should be made to product literature for dimensions,
operating parameters, part numbering, ordering information
and specifications. 
6.1

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. 

6.2

If visual indicator is fitted and actuates during 'cold start'
(red button extends 5mm, 3/16"), reset by depressing the
button when the normal operating temperature is reached.
If indicator actuates after resetting, replace element. 

NOTE: Option 'P' visual indicator has thermal lockout and manual
reset. No signal below 0°C (32°F), signal above 29°C (80°F).

6.3

If the electrical switch actuates (e.g. red light comes on)
during cold start, continue operating until the signal (red
light) goes out as system warms to normal operating
temperature. This feature can be used as 'warm up'
indication in operating procedures. If the warning signal
(red light) remains or appears when system is warm,
replace the filter element.

ENGLISH

6.4

Use of both positive indication (green light) and negative
indication (red light for dirty element) is recommended to
effectively monitor filter element life.

Electrical connections and ratings for all differential
pressure switch options:

110 VAC

=

4A (inductive),
4A (resistive)

220 VAC

=

4A (inductive),
4A (resistive)

28 VDC

=

3A (inductive),
5A (resistive)

48 VDC

=

1A (inductive),
1.5A (resistive)

125 VDC

=

0.25A (inductive),
0.5A (resistive)

Maximum inrush - 24 amps.
Underwriter’s lab. Inc. listed ratings of pressure switch
(Microswitch) options are:
4 amps at 250 VAC
0.25 amp resistive at 220 VDC
0.50 amp resistive at 110 VDC

Electrical differential pressure switch operation:

When preset differential pressure is exceeded continuity
switches from 'C' - 'A' to 'C' - 'B'.
When differential pressure decreases below the pre-set value,
continuity returns to 'C' - 'A'.

Figure 1 

- Switch Circuit Diagram

C
or black
or tag 2

CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.

A
or white
or tag 1

B
or red
or tag 3

LOW DIFFERENTIAL PRESSURE

HIGH DIFFERENTIAL PRESSURE

Содержание UH319C Series

Страница 1: ...UH319 UH319 Series service instructions UK60898 IMSIUH319c EN UH319 Service Instructions ENGLISH ...

Страница 2: ... is as follows 4 2 1 UH319C series cover service 205mm 8 1in for length 8 340mm 13 4in for length 13 510mm 20in for length 20 and 1020mm 40 2in for length 40 housings 4 2 2 UH319H series head service 138mm 5 5in for all lengths 4 2 3 The UH319 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices...

Страница 3: ...abels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 ...

Страница 4: ...its Servicing must be conducted using suitable tools that do not present a hazard Servicing must not be carried out when a potentially explosive atmosphere is present Refer to Service Parts List Section 9 for item numbers for applicable replacement element series Remove and replace element as follows 7 1 Turn off and depressurize the system 7 1 1 For UH319C series cover service Open vent plug 7 at...

Страница 5: ...tered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in us...

Страница 6: ...UH319 UH319 Series s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Not shown on this diagram Not shown on this diagram Inlet HIGH PRESSURE FILTERS ...

Страница 7: ...ondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 7 mm M12 x 1 75 19 mm E24 11 2 1 437 3 125 5 8 11 UNC 1 38 G24 11 2 36 5 mm 79 4 mm M16 x 2 00 35 mm E32 2 1 750 3 812 3 4 10 UNC 1 5 G...

Страница 8: ... 2008 Printed in England IMSIUH319c Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan...

Отзывы: