7.4

DO NOT run the system without a filter element
installed. Check that the O-ring between the bowl (2)
and head (1) is not damaged. Use the replacement filter
as indicated by the part number on the element endcap. 

7.5

Lubricate element O-ring with clean system fluid. 
Reinstall element in the shell assembly. Lightly lubricate 
head-to-bowl O-ring with clean system fluid and 
reassemble the housing until thread bottoms. 
The bowl should be torque tightened using a suitable 
socket wrench to 74 ft/lb or 100 Nm.
O-ring sealing is not improved by over tightening

7.6

Bleed the system and check for leaks as per section 5.2.

7.7

After element change ENSURE DIFFERENTIAL 
PRESSURE DEVICE IS RESET BY PUSHING IN THE 
RED BUTTON; electrical switches reset automatically. 
When system reaches normal operating temperature, 
check that the electrical switch has not actuated and/or 
the visual warning button has remained depressed. If 
visual indicator rises due to a cold start condition, reset 
again as per section 6.

8

Fluid Sampling

Optimum sampling to verify fluid condition can be achieved 
by the use of sampling adaptors installed in place of or in
combination with the differential pressure device. For more
information consult Pall or your local Pall Distributor.
Pall offers a fluid contamination analysis service – consult the
Pall sales office

9

Warranty, Limitation of Liability and
Remedies

THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WITH RESPECT
TO ANY OF THE PRODUCTS, NOR IS THERE ANY OTHER
WARRANTY EXPRESS OR IMPLIED, EXCEPT AS PROVIDED
FOR HEREIN.
For a period of twelve months from the date of delivery from
Seller or three thousand hours of use, whichever occurs first
(the "Warranty Period"), Seller warrants that products
manufactured by Seller when properly installed and
maintained, and operated at ratings, specifications and design
conditions, will be free from defects in material and
workmanship. By way of explanation and not limitation, the
Seller does not warrant the service life of the filter element as
this is beyond the Seller's control and depends upon the
condition of the system into which the filter is installed.

4

7

Filter element installation / servicing

During servicing, the external surfaces of the filter assembly
must be cleaned to remove any dust deposits. 
Servicing must be conducted using suitable tools that do not
present a hazard. Servicing must not be carried out when a
potentially explosive atmosphere is present.

Refer to Service Parts List (Section 10) for item numbers for
applicable replacement element series. Remove and replace
element as follows:
7.1 

Turn off and depressurize the system. 

7.2

Unscrew and remove the filter bowl assembly (2) from
head (1) counter-clockwise when viewed from below. It
will be necessary to use a 1" socket wrench on the
hexagon on the bowl to initially loosen the bowl.

7.3

Element replacement (UE209 Series): Remove filter 
element (5), if already fitted, and carefully inspect the 
interior surface (flow through the element is in-to-out) for
visible contamination. Normally no dirt should show, but 
visible dirt or particles can be an early warning of 
system component failure. Discard both the filter 
element and its O-ring. The filter element is NOT 
CLEANABLE. Any attempt to clean the filter element 
can cause degradation of the filter medium and allow 
contaminated fluid to pass through the filter element.

WARNING:
FAILURE TO DEPRESSURISE THE FILTER BEFORE
SERVICING ELEMENT COULD RESULT IN
EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.

WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE THE
ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.

CAUTION:
Filter elements should be replaced upon indication or
at specified intervals, six months maximum. Failure to
change the element will cause the filter to go on
bypass.

Содержание UH209 Series

Страница 1: ...UH209 UH209 Series service instructions IMSIUH209 EN UH209 Service Instructions ENGLISH ...

Страница 2: ...installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when fitted must be torque tightened to 38 ft lb or 54 Nm All visual indicators must be clearly visible NOTE The UH209 head is supplied with one machined differential pressure warning port fitted with a plastic shipping plug If no differential pressure warning device is to be installed the shipping ...

Страница 3: ...tart conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 16 reset by depressing the button when the normal operating temperature is reached If indicator actuates after resetting replace element NOTE Option P visual indicator has thermal lockout and manual reset No signal below 0 C 32 F signal above 29 C 80 F 6 3 If the electrical switch actuates e g...

Страница 4: ...ntained and operated at ratings specifications and design conditions will be free from defects in material and workmanship By way of explanation and not limitation the Seller does not warrant the service life of the filter element as this is beyond the Seller s control and depends upon the condition of the system into which the filter is installed 4 7 Filter element installation servicing During s...

Страница 5: ...e liable for any product altered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration a...

Страница 6: ...UH209 UH209 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 5 3 Figure 2 1 Inlet ...

Страница 7: ...UH209 UH209 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Страница 8: ...2008 Printed in England IMSIUH209 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan T...

Отзывы: