ITALIANO
ENGLISH
FRANÇAIS
004778560 - 17/11/2020
89
8.2 Configuration 2 - Room thermostat
1
6
1
2
3
4
5
6
Sonda temperatura
ambiente
T
22.15
20.3 °C
Termostato esterno
Room temperature
probe
External thermostat
Fig. 50
In configuration 2 the appliance is controlled
by a external thermostat (or programmable
thermostat) (not supplied), which switches the
appliance on and off depending on the set tem-
perature (
When the temperature is satisfied, the thermo-
stat opens the circuit and switches off the stove.
The stove switches back on automatically when
the temperature falls below the value set on the
external thermostat (closed circuit).
This configuration can also be used to turn
the appliance on and off manually or in a pro-
grammed way (with the Timer function active);
to do this it is necessary to put a bridge between
the two terminals.
If the thermostat allows scheduled
programming, to avoid overlapping
operation time slots, it is advisable to
deactivate the appliance timer by set-
ting it to OFF.
In this configuration the appliance
turns off when the external thermo-
stat is satisfied, or it will modulate the
power (to keep consumption to a mini-
mum) when the set room temperature
is reached.