26
6 ALARM MANAGEMENT
If a malfunction occurs, the following procedure is activated:
1)
audible alarm (beep);
2) one of the following system LEDs come on:
;
3)
if the problem concerns an error, the stove will switch off.
Pressing and holding the “cancel” button shows the error code on the display:
ERROR/
WARNING CODE
DESCRIPTION
POSSIBLE CAUSES
LED
E001
Faulty control panel
Control panel fault
E002
Remote control signal communication error
Control panel fault
E004
Communication error
Connection cable between board and control panel
interrupted or detached.
If this appears when changing configuration, ignore
the error
E101
Failed ignition error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
E105
Pellet probe malfunction
Pellet probe disconnected or faulty
E106
Temperature probe malfunction
Faulty air temperature probe
E108
*
Safety error
Door or hopper lid open
E109
Pressure error or thermal safety
Flue gas exhaust system dirty
Seal gaskets worn
Insufficient combustion air
Problems with overheating in the pellet hopper
E110
Temperature probe malfunction
Faulty air temperature probe
E111
Flue gas temperature probe malfunction
Faulty flue gas temperature probe
A001
Low pellet level
(icon flashing)
Pellets running out
A002
Scheduled maintenance warning
(icons flashing)
The stove periodically requires maintenance to be
performed by a qualified technician
A007
Pressure sensor malfunction
(icon flashing)
Pressure sensor or board fault.
----
Clean stove
Combustion chamber, burn pot or flue gas exhaust
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
----
Failed ignition error
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position
* Only for the models equipped with safety microswitches on the door or on the hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/off button
for a few
moments.
If the error code is “
E109
”, before resetting the alarm, manually reset the thermostat located on the rear of the
stove (Fig. 6.1)
( this should be carried out by an authorized technician).
Before proceeding with a new ignition, check that:
•
the stove has cooled
•
the burning pot is clean and free of any ash residue or pellet
•
the burning pot is correctly positioned in its seat
•
the doors of the hearth and the tank are perfectly closed
fig. 6.1