7.6.7.4 Turning the stove off
To turn the stove off press the
OFF
button for a few
seconds. “
FINAL CLEANING
” (Fig. 7.6.55) will appear
on the display.
The pellet loading screw stops immediately while the
ventilators will stop automatically when the stove is
cold.
)
To light the stove again it is recommended to wait
until it is completely cold.
)
It is possible to set the operating parameters of the
stove.
In the case where it is attempted to restart the stove, it
is possible that the display will indicate “
AWAITING
CLEANING TO FINISH
” which invites the user to wait
for the complete switch-off.
The settings will only be activated during the work
phase, in fact, the switch-off phase “
FINAL CLEANING
”
is automatically set.
!
Do not take the plug out of the mains to turn the
stove off Let the automatic turning off phase finish.
Protracted functioning of the smoke outlet fan is
normal.
7.6.7.4 Ausschalten des Heizofens
Zum Ausschalten des Heizofens die
OFF
-Taste einige
Sekunden lang drücken. Auf dem Display erscheint
die Meldung
ENDREINIGUNG
(Abb. 7.6.55).
Die Beschickungsschnecke bleibt gleich stehen,
während die Ventilatoren automatisch stehen bleiben,
wenn der Heizofen abgekühlt ist.
)
Warten Sie zur Durchführung einer neuen Zündung,
bis der Heizofen komplett abgekühlt ist.
)
Es ist möglich, die Betriebsparameter des Heizofens
einzustellen.
Beim Versuch einer neuen Zündung kann auf dem
Display die Meldung “
WARTEN AUF REINIGUNGSENDE
”
erscheinen, die den Benutzer dazu auffordert, die
komplette Abschaltung abzuwarten.
Die Einstellungen sind nur während der
Betriebsphase aktiv. Die Abschaltphase
“
ENDREINIGUNG
” wird dagegen automatisch
eingestellt.
!
Zum Ausschalten des Heizofens nicht den Stecker
aus der Dose ziehen. Den automatischen
Abschaltzyklus unbedingt beenden lassen. Ein länger
andauernder Betrieb des Rauchabzugventilators gilt
als normal.