18
'HVFULSWLRQRIWKHPHQXV
ICON
FUNCTION
DESCRIPTION
VALUES
Power
Stove output setting
1..5
Fan
*
where featured)
It allows you to set the fan speed.
OFF*,1..5; Auto; Hi
Temperature
Displays the room temperature reading and is used to set the desired
temperature.
6°C .. 51°C
Fuel
Not used
Timer
Enables or disables the timer. When enabled, the icon
will be
displayed steady
not
À
ashing)
ON - OFF
ICON
FUNCTION
SUBMENU
DESCRIPTION
VALUES
Setup
[1]
Weekly timer
Assigns the programs
max 3) to the different days of the
week
[d1] ... [d7]
[2]
Programs
Program setting menu
[P1] ... [P6]
[3]
Time / date
Time and date setting
[4]
Hours remaining
Displays the number of hours remaining until recommended
maintenance. When “Hi” is displayed, the remaining time
exceeds
hours.
[5]
System
information
Displays the current software version
[6]
Function not enabled
[7]
Eco function
Enables or disables Eco Mode, in which the stove
automatically switches off and on based on room temperature
only in con
¿
guration 1).
OFF; Eco
[8]
Restart delta
Difference in degrees from room temperature below which
the stove switches on again
only in con
¿
guration 1).
0,5 ... 5,0°C
[9]
Frost protection
temperature
Minimum temperature below which the stove switches on
only in con
¿
guration 1).
OFF; 3 ... 20 °C
[10]
Lock keypad
Disables the buttons on the keypad
OFF; Lo; Hi
[11]
Display brightness Sets display brightness
OFF; 1 ... 5
[12]
Display mode
Sets how the data is displayed
OFF; 1 ... 4
[13]
Buzzer volume
Sets the buzzer volume
OFF; 1 ... 5
[14]
Combustion
Three different types of combustion can be set
1 ... 3
[15]
Function not enabled
[30]
Installer menu
Sets/displays the stove configuration
PWD: “54”
[40]
Service menu
Menu reserved for the service centre
Submenus
[30]
and
[40]
in the Setup menu are password-protected and reserved for service centre personnel.
USING THE CONTROL PANEL
•
The arrow buttons
are used to scroll between the different menus that are highlighted.
•
When selecting a given function, simply press the
button and then modify the values, again using the
buttons.
• Pressing
the button con
¿
rms the setting.
•
In general all values that are
À
ashing can be modi
¿
ed using the
buttons.
• The
“cancel”
button is used to cancel any changes; pressing and holding the button displays any active
alarm or error codes.